Liletta Intrauterine Device
Product Images NDC 0023-5858

23 FDA label images from Allergan, Inc. · Packaging, Regulatory Labels, and Product Appearance

Product Visual Gallery

This gallery contains 23 technical images submitted to the FDA as part of the official labeling for Liletta (NDC 0023-5858). Unlike standard consumer photos, these assets often include clinical data figures, molecular chemical structures, and official manufacturer packaging layouts.

As provided by Allergan, Inc., these visuals offer a comprehensive scientific overview of the product's physical and chemical identity, aiding pharmacists and researchers in product verification and study.

FDA Label Image

Figure 1b: Liletta Ius With Inserter (Liletta Shi 02)

Figure 1b: Liletta Ius With Inserter (Liletta Shi 02)
An instructional diagram labeled 'LILETTA IUS' showing the T-shaped intrauterine device with dimensions 32 mm by 32 mm. Key parts identified include the T-shaped plastic frame, hormone reservoir with membrane, and blue removal threads extending from the bottom.*
FDA Label Image

Figure 2: Inserter Sliders (Liletta Shi 03)

Figure 2:  Inserter Sliders (Liletta Shi 03)
An instructional diagram of the LILETTA levonorgestrel intrauterine device (IUD) showing labeled parts including the insertion tube, flange, blue slider, green slider, handle, cleft, and threads. The device is illustrated in a vertical orientation with clear identification of its components for insertion and positioning.*
FDA Label Image

Figure 3: Sliders Completely Forward For Loading Liletta (Liletta Shi 04)

Figure 3:  Sliders Completely Forward For Loading Liletta (Liletta Shi 04)
An instructional diagram showing the inserter device for LILETTA intrauterine device (52 mg Levonorgestrel). The image highlights the handle with a blue slider labeled "1" (single line marking) and a green slider labeled "2" (double line marking), which assist in the insertion process. Text explains that moving the sliders achieves the positions required for device insertion.*
FDA Label Image

Figure 4: Locking The Threads In Cleft (Liletta Shi 05)

Figure 4:  Locking The Threads In Cleft (Liletta Shi 05)
An instructional illustration showing a gloved hand holding an intrauterine device (IUD) applicator. The image depicts the mechanism for rotating or releasing the device from its packaging, with an arrow indicating a clockwise motion. The device shown corresponds to the LILETTA intrauterine device for levonorgestrel delivery.*
FDA Label Image

Figure 5: Close-up Of Hemispherical Dome At Tip Of Tube (Liletta Shi 06)

Figure 5:  Close-up Of Hemispherical Dome At Tip Of Tube (Liletta Shi 06)
An instructional illustration showing a hand holding the LILETTA 52 mg intrauterine device (IUD) delivery system. The image highlights the single line and double line markings labeled as Number 1 and Number 2 on the device, with an emphasis on maintaining forward pressure on the blue slider during insertion.*
FDA Label Image

Figure 6: Adjusting The Flange (Liletta Shi 07)

Figure 6: Adjusting The Flange (Liletta Shi 07)
An instructional illustration showing close-up views of a hand manipulating a string threaded through the tip of a cylindrical applicator device, likely demonstrating how to handle or release the string associated with an intrauterine device (IUD).*
FDA Label Image

Figure 7: Advancing Insertion Tube Until Flange Is 1.5 To 2 Cm From The External Cervix (Liletta Shi 08)

Figure 7:  Advancing Insertion Tube Until Flange Is 1.5 To 2 Cm From The External Cervix (Liletta Shi 08)
LILETTA intrauterine device containing 52 mg of levonorgestrel. The image shows a close-up view of the white plastic IUD with a rounded, smooth tip and notched sides. The device is designed for intrauterine use and is manufactured by Allergan, Inc.*
FDA Label Image

Figure 8: Releasing And Opening The Arms Of The Ius (Liletta Shi 09)

Figure 8:  Releasing And Opening The Arms Of The Ius (Liletta Shi 09)
An instructional illustration showing a gloved hand retrieving an intrauterine device (IUD) from a tray. The tray features a notch labeled 'Tray notch' to assist in device removal. This diagram is associated with LILETTA (Levonorgestrel) 52 mg intrauterine device by Allergan, Inc.*
FDA Label Image

Figure 9: Move Liletta Into The Fundal Position (Liletta Shi 0a)

Figure 9:  Move Liletta Into The Fundal Position (Liletta Shi 0a)
An instructional diagram showing the placement of the LILETTA intrauterine device (IUD) within the uterus. The image includes a hand holding the IUD inserter, with arrows indicating the direction of insertion and instructions to maintain forward pressure on the blue slider. The diagram also notes the recommended depth placement of 1.5 cm to 2 cm inside the uterus.*
FDA Label Image

Figure 10: Releasing Liletta From The Inserter Tube (Liletta Shi 0b)

Figure 10:  Releasing Liletta From The Inserter Tube (Liletta Shi 0b)
Instructional diagram showing the insertion technique for the intrauterine device LILETTA (Levonorgestrel 52 mg). Illustrations depict a gloved hand holding the device, the operation of blue and green sliders on the applicator, and the placement of the device's arms inside the uterus as viewed within an anatomical outline.*
FDA Label Image

Figure 11: Green Indicator Visible And Threads Released From Cleft (Liletta Shi 0c)

Figure 11:  Green Indicator Visible And Threads Released From Cleft (Liletta Shi 0c)
An instructional illustration showing a gloved hand holding an intrauterine device (IUD) insertion tool with arrows indicating upward movement. The diagram depicts the female reproductive anatomy highlighting the placement of the device inside the uterus, demonstrating part of the IUD insertion procedure.*
FDA Label Image

Figure 12: Cut The Threads About 3 Cm From The Cervix (Liletta Shi 0d)

Figure 12:  Cut The Threads About 3 Cm From The Cervix (Liletta Shi 0d)
An instructional illustration showing the insertion of the LILETTA intrauterine device (IUD) into the uterus. The diagram highlights hand positioning on the insertion device, with a close-up emphasizing the maintenance of the joint slider recess while moving the sliders down together during placement.*
FDA Label Image

Figure 13: Removal Of Liletta (Liletta Shi 0e)

Figure 13: Removal Of Liletta (Liletta Shi 0e)
Illustration of the LILETTA intrauterine device (IUD) inserter tip showing the green indicator used during device placement. The image highlights the portion of the inserter with the green indicator to aid accurate intrauterine insertion of the Levonorgestrel 52 mg IUD.*
FDA Label Image

Structural Formula (Liletta Shi 0f)

Structural Formula (Liletta Shi 0f)
Illustration showing the placement of the LILETTA intrauterine device (IUD) inside the uterus. The diagram includes insertion instruments and indicates a 3 cm measurement from the cervix to a point inside the vaginal canal.*
FDA Label Image

Figure 14: Diagram Of Liletta (Liletta Shi 10)

Figure 14: Diagram Of Liletta (Liletta Shi 10)
Illustration showing the intrauterine device LILETTA with instructions to withdraw it from the uterus by pulling on the attached removal string. The diagram outlines the uterus and the correct direction to remove the device.*
FDA Label Image

Figure 15: Diagram Of Inserter (Liletta Shi 11)

Figure 15: Diagram Of Inserter (Liletta Shi 11)
Chemical structure of levonorgestrel, the active ingredient in LILETTA 52 mg intrauterine device by Allergan, Inc. The diagram depicts the molecular structure with carbon rings, hydroxyl group, and other characteristic bonds.*
FDA Label Image

Liletta Is Small And Flexible. (Liletta Shi 12)

Liletta Is Small And Flexible. (Liletta Shi 12)
Illustration showing the components of the LILETTA levonorgestrel intrauterine device (IUD) unassembled, including the T-frame, membrane, drug reservoir, and eyelet, alongside an assembled LILETTA IUS with dimensions labeled as 32 mm by 32 mm.*
FDA Label Image

Liletta Is Small And Flexible. (Liletta Shi 13)

Liletta Is Small And Flexible. (Liletta Shi 13)
Illustration of the LILETTA 52 mg intrauterine device (IUD) showing labeled components including the insertion tube, flange, blue and green sliders, handle, cleft, and threads. The diagram presents the device parts used for intrauterine placement of the levonorgestrel IUD.*
FDA Label Image

How Does Liletta Work? (Liletta Shi 14)

How Does Liletta Work? (Liletta Shi 14)
Illustration of the LILETTA intrauterine device (IUD) showing its size relative to an adult human hand. The device is T-shaped with a vertical stem and horizontal arms, with a visible string extending from the base for removal or positioning.*
FDA Label Image

Liletta, An Intrauterine System (ius), Is In The Box At The Top Of The Chart. (Liletta Shi 15)

Liletta, An Intrauterine System (ius), Is In The Box At The Top Of The Chart. (Liletta Shi 15)
A black and white photograph showing a hand holding an intrauterine device (IUD) by its string. The IUD is small and T-shaped, likely representing the LILETTA levonorgestrel intrauterine device.*
FDA Label Image

Principal Display Panelndc 0023-5858-01rx Onlyliletta® (levonorgestrel-releasing Intrauterine System) 52 mg (Liletta Shi 16)

Principal Display Panelndc 0023-5858-01rx Onlyliletta® (levonorgestrel-releasing Intrauterine System) 52 mg (Liletta Shi 16)
An anatomical diagram of the female reproductive system showing the placement of the LILETTA intrauterine device containing levonorgestrel. The diagram labels the vaginal canal, uterus, fallopian tubes, ovaries, and highlights the IUD's effects such as thinning of the uterine lining, inhibition of sperm movement, and thickening of cervical mucus.*
FDA Label Image

Liletta Shi 17

Liletta Shi 17
A chart depicting pregnancy rates per 100 women in one year associated with different birth control methods. The vertical axis ranges from fewer pregnancies (fewer than 1 per 100 women) at the top, to more pregnancies (85 or more per 100 women) at the bottom. Methods are grouped in boxes, with implants, intrauterine devices, and sterilization linked to the fewest pregnancies, while no birth control is associated with the most pregnancies.*
FDA Label Image

Liletta Shi 18

Liletta Shi 18
LILETTA 52 mg intrauterine device packaging label showing a levonorgestrel-releasing intrauterine system. The label highlights an updated inserter design and specifies that the product is a single-handed insertion device for intrauterine use. The labeler is Allergan, Inc., and it includes product and insertion instructions, along with NDC 0023-5858-01 and a note that the device is sterile for single use.*

* About these descriptions: Image descriptions on this page are generated by automated AI analysis of the product label images from the manufacturer's FDA label submission (SPL). They are provided for reference only and may contain errors or omissions. Always rely on the printed label itself and the official FDA labeling, and consult a pharmacist or healthcare professional with any questions about this product.