Jivi Kit
Product Images NDC 0026-3948

28 FDA label images from Bayer Healthcare Llc · Packaging, Regulatory Labels, and Product Appearance

Product Visual Gallery

This gallery contains 28 technical images submitted to the FDA as part of the official labeling for Jivi (NDC 0026-3948). Unlike standard consumer photos, these assets often include clinical data figures, molecular chemical structures, and official manufacturer packaging layouts.

As provided by Bayer Healthcare Llc, these visuals offer a comprehensive scientific overview of the product's physical and chemical identity, aiding pharmacists and researchers in product verification and study.

FDA Label Image

Image (Jivi 01)

Image (Jivi 01)
Illustration showing a hand holding a vial with a capped top, demonstrating the step of removing the cap by pulling it upward. This is likely part of the preparation instructions for the Jivi (Antihemophilic Factor recombinant pegylated-aucl) kit by Bayer HealthCare LLC.*
FDA Label Image

Image (Jivi 02)

Image (Jivi 02)
An instructional illustration showing hands assembling or connecting components of a kit, likely for Jivi (Antihemophilic Factor Recombinant Pegylated-aucl). The image highlights placing one piece onto another as indicated by a downward arrow, suggesting part of the preparation or assembly process for the medication kit.*
FDA Label Image

Image (Jivi 03)

Image (Jivi 03)
An instructional illustration showing a hand pulling the cap off a vial or container. The image demonstrates how to remove the cap from a tube or vial, which could be part of the preparation steps for a Jivi (Antihemophilic Factor Recombinant Pegylated-aucl) kit.*
FDA Label Image

Image (Jivi 04)

Image (Jivi 04)
An instructional illustration showing a close-up of hands assembling or connecting two components by aligning them and pushing together, indicated by an arrow pointing upwards. This diagram likely relates to the proper assembly or preparation of the Jivi kit components.*
FDA Label Image

Image (Jivi 05)

Image (Jivi 05)
An instructional illustration showing a close-up of hands manipulating a syringe and vial. The image depicts the process of attaching the syringe to the vial, with an arrow indicating the twisting or turning motion required.*
FDA Label Image

Image (Jivi 06)

Image (Jivi 06)
Illustration showing the process of twisting or securing a component, likely related to preparation or assembly of the Jivi (Antihemophilic Factor (Recombinant) Pegylated-aucl) kit.*
FDA Label Image

Image (Jivi 07)

Image (Jivi 07)
An instructional illustration showing a hand pressing down on a plunger or stopper of a vial or container, indicating an action likely related to medication preparation or kit use. The image is simple with black and white line art and an arrow pointing downward to show the direction of the pressing motion.*
FDA Label Image

Image (Jivi 08)

Image (Jivi 08)
An instructional diagram showing a hand holding a vial stopper or cap, positioned above a vial. Arrows indicate a twisting or turning motion to remove or secure the stopper on the vial, suggesting a step for vial preparation or access.*
FDA Label Image

Image (Jivi 09)

Image (Jivi 09)
An instructional illustration showing a person using their hands to pull a syringe or vial upward from a stopper or holder, indicated by an arrow pointing up. This likely represents a preparation step for a medication kit, such as assembling or drawing up a dose.*
FDA Label Image

Image (Jivi 10)

Image (Jivi 10)
An instructional illustration showing a syringe being prepared or used, with a hand holding the syringe and another hand holding a small cap or stopper, with an arrow pointing downward indicating a step in the process.*
FDA Label Image

Image (Jivi 11)

Image (Jivi 11)
An instructional illustration showing two hands assembling medical components. One hand holds a vial or container while the other hand inserts or twists a connector onto the vial, indicated by a curved arrow suggesting a turning motion. The letter 'K' is displayed in the top right corner, possibly indicating a step in a sequence.*
FDA Label Image

Image (Jivi 12)

Image (Jivi 12)
An instructional illustration showing components of the Jivi kit including a vial with protective cap, a vial adapter with plastic housing and paper cover, a pre-filled syringe displaying syringe tip, barrel, syringe cap, and threaded rubber stopper, and a plunger rod with thread and top plate.*
FDA Label Image

Image (Jivi 13)

Image (Jivi 13)
An instructional illustration showing a hand holding a vial and turning or removing its cap, likely demonstrating the first step of preparing or opening the Jivi medication kit.*
FDA Label Image

Image (Jivi 14)

Image (Jivi 14)
An instructional black-and-white line drawing showing hands attaching or securing one medical device component to another, indicated by a downward arrow. The image likely depicts part of the assembly or preparation process for a medical kit, possibly for Jivi (Antihemophilic Factor, Recombinant) Pegylated-aucl.*
FDA Label Image

Image (Jivi 15)

Image (Jivi 15)
An instructional illustration showing hands opening or twisting off the cap of a vial or container, indicating the initial step for preparing or administering the Jivi Antihemophilic Factor (Recombinant) Pegylated-aucl kit.*
FDA Label Image

Image (Jivi 16)

Image (Jivi 16)
An instructional diagram showing hands assembling or attaching a component to a bottle or vial, indicated by an arrow pointing upward. The image likely demonstrates a step in preparing or using the Jivi kit, which contains Antihemophilic Factor (Recombinant) Pegylated-aucl.*
FDA Label Image

Image (Jivi 17)

Image (Jivi 17)
An instructional illustration depicting a person using a syringe to withdraw a solution from a vial. The image focuses on hands holding the vial and syringe, showing the preparation step often used in medication administration kits.*
FDA Label Image

Image (Jivi 18)

Image (Jivi 18)
Instructional illustration showing the preparation step of connecting a syringe to a vial adapter in the Jivi kit for Antihemophilic Factor (Recombinant) Pegylated-aucl. The image depicts hands aligning and attaching components as part of the medication reconstitution process.*
FDA Label Image

Image (Jivi 19)

Image (Jivi 19)
An instructional illustration showing a hand holding a syringe and aligning it with a vial, with an arrow indicating the syringe is being inserted downward into the vial. This image is likely part of preparation or administration instructions for Jivi, an Antihemophilic Factor (Recombinant) Pegylated-aucl kit by Bayer HealthCare LLC.*
FDA Label Image

Image (Jivi 20)

Image (Jivi 20)
An instructional illustration showing a hand holding a vial and twisting or removing a cap or stopper from the vial. The vial is depicted with arrows indicating a rotational motion, suggesting the action needed to open or prepare the vial for use in the Jivi kit.*
FDA Label Image

Image (Jivi 21)

Image (Jivi 21)
An instructional illustration showing hands handling a vial and syringe. One hand is holding the vial upside down, while the other hand is pulling the plunger of the syringe, indicated by an upward arrow, suggesting the withdrawal of liquid from the vial.*
FDA Label Image

Image (Jivi 22)

Image (Jivi 22)
An instructional illustration depicting a hand holding a syringe and another hand drawing liquid into the syringe, indicated by a downward arrow. The image is likely part of the Jivi (Antihemophilic Factor, Recombinant) Pegylated-aucl kit instructions for use.*
FDA Label Image

Image (Jivi 23)

Image (Jivi 23)
An instructional diagram showing hands preparing a vial and an ampule, with an arrow indicating a twisting or turning motion to open or connect them. The letter 'K' is visible in the top right corner, likely denoting a step in a sequence.*
FDA Label Image

500 Iu Carton (Jivi 24)

500 Iu Carton (Jivi 24)
Packaging label for Jivi 500 IU Range kit containing Antihemophilic Factor (Recombinant) Pegylated-aucl, a plasma derivative. The label shows the Bayer HealthCare LLC logo and specifies the product includes a needleless reconstitution set and vial adapter, intended for intravenous use only. The NDC 0026-3942-25 is visible on the label.*
FDA Label Image

1000 Iu Carton (Jivi 25)

1000 Iu Carton (Jivi 25)
Packaging label for Jivi 1000 IU Range Kit, containing Antihemophilic Factor (Recombinant) Pegylated-aucl, Recombinant Factor VIII. The kit is labeled for intravenous use only and includes a needleless reconstitution set and vial adapter. Manufactured by Bayer HealthCare LLC.*
FDA Label Image

2000 Iu Carton (Jivi 26)

2000 Iu Carton (Jivi 26)
Package label for Jivi 2000 IU Range, an Antihemophilic Factor (Recombinant) Pegylated-aucl kit containing Recombinant Factor VIII. The label shows the product is a needleless reconstitution set with vial adapter for intravenous use only. Labeler is Bayer HealthCare LLC. Directions indicate reconstitution with 2.5 mL sterile water for injection, USP, and administration within 3 hours after reconstitution.*
FDA Label Image

3000 Iu Carton (Jivi 27)

3000 Iu Carton (Jivi 27)
Packaging label for Jivi 3000 IU Range kit containing Antihemophilic Factor (Recombinant) Pegylated-aucl, a recombinant factor VIII product. The label indicates it includes a vial adapter and is a needleless reconstitution set for intravenous use only. The product is labeled by Bayer HealthCare LLC.*
FDA Label Image

4000 Iu Carton (Jivi 28)

4000 Iu Carton (Jivi 28)
Packaging label for Jivi 4000 IU Range kit containing Antihemophilic Factor (Recombinant) Pegylated-aucl, a recombinant Factor VIII product. The label shows it is a single-dose vial with a needleless reconstitution set and vial adapter for intravenous use only. The product is labeled by Bayer HealthCare LLC.*

* About these descriptions: Image descriptions on this page are generated by automated AI analysis of the product label images from the manufacturer's FDA label submission (SPL). They are provided for reference only and may contain errors or omissions. Always rely on the printed label itself and the official FDA labeling, and consult a pharmacist or healthcare professional with any questions about this product.