Important Administration Instructions
• This reconstituted solution is for intravenous use only.
• Administer Cefoxitin for Injection and Dextrose Injection intravenously over approximately 30 minutes.
• Do not use in series connections. Such use would result in air embolism due to residual air being drawn from the primary container before administration of the fluid from the secondary container is complete. If administration is controlled by a pumping device, care must be taken to discontinue pumping action before the container runs dry or air embolism may result.
• Do not introduce additives into the DUPLEX® Container.
• Cefoxitin for Injection and Dextrose Injection may be administered through the tubing system by which the patient may be receiving other intravenous solutions. However, during infusion of the solution containing Cefoxitin for Injection and Dextrose Injection, it is advisable to temporarily discontinue administration of any other solutions at the same site.
• Cefoxitin for Injection and Dextrose Injection, like most beta-lactam antibiotics, should not be added to aminoglycoside solutions (e.g., gentamicin sulfate, tobramycin sulfate, amikacin sulfate) because of potential interaction. However, Cefoxitin for Injection and Dextrose Injection and aminoglycosides may be administered separately to the same patient.
Parenteral drug products should be inspected visually for particulate matter and discoloration
prior to administration, whenever solution and container permit.
Use only if solution is clear and free from particulate matter and container and seals are intact. As with other cephalosporins, reconstituted Cefoxitin for Injection and Dextrose Injection tends to darken depending on storage conditions, within the stated recommendations. However, product potency is not adversely affected.
DUPLEX® Container Storage
• To avoid inadvertent activation, DUPLEX® Container should remain in the folded position until activation is intended.
Patient Labeling and Drug Powder/Diluent Inspection
• Apply patient-specific label on foil side of container. Use care to avoid activation. Do not cover any portion of foil strip with patient label.
• Unlatch side tab and unfold DUPLEX® Container (see Diagram 1).
Diagram 1 Illustration (Cefoxitin For Injection And Dextrose Injection In 1)
• Visually inspect diluent chamber for particulate matter.
• Use only if container and seals are intact.
• To inspect the drug powder for foreign matter or discoloration, peel foil strip from drug chamber (see Diagram 2).
Diagram 2 Illustration (Cefoxitin For Injection And Dextrose Injection In 2)
• Protect from light after removal of foil strip.
• Note: If foil strip is removed, the container should be re-folded and the side tab latched until ready to activate. The product must then be used within 7 days, but not beyond the labeled expiration date.
Reconstitution (Activation)
• Do not use directly after storage by refrigeration, allow the product to equilibrate to room temperature before patient use.
• Unfold the DUPLEX® Container and point the set port in a downward direction. Starting at the hanger tab end, fold the DUPLEX® Container just below the diluent meniscus trapping all air above the fold. To activate, squeeze the folded diluent chamber until the seal between the diluent and powder opens, releasing diluent into the drug powder chamber (see Diagram 3).
Diagram 3 Illustration (Cefoxitin For Injection And Dextrose Injection In 3)
• Agitate the liquid-powder mixture until the drug powder is completely dissolved.
Note: Following reconstitution (activation), product must be used within 12 hours if stored at room temperature or within 7 days if stored under refrigeration.
Administration
• Visually inspect the reconstituted solution for particulate matter.
• Point the set port in a downwards direction. Starting at the hanger tab end, fold the DUPLEX® Container just below the solution meniscus trapping all air above the fold. Squeeze the folded DUPLEX® Container until the seal between reconstituted drug solution and set port opens, releasing liquid to set port (see Diagram 4).
Diagram 4 Illustration (Cefoxitin For Injection And Dextrose Injection In 4)
• Prior to attaching the IV set, check for minute leaks by squeezing container firmly. If leaks are found, discard container and solution as sterility may be compromised.
• Using aseptic technique, peel foil cover from the set port and attach sterile administration set (see Diagram 5).
Diagram 5 Illustration (Cefoxitin For Injection And Dextrose Injection In 5)
• Refer to Directions for Use accompanying the administration set.
• Discard unused portions.