Tisseel Frozen 2ml Representative Pouch Label (NDC 0338-8402-01)
Tiseel Frozen 2 mL Pouch LabelFibrin Sealant
TISSEEL 2 mL
NDC 0338-8402-01
Vapor Heated, Solvent/Detergent Treated, Frozen
Baxter Logo
Temperature sensitive – Do NOT expose above 37°C (99°F).
TOPICAL USE ONLY DO NOT INJECT
Read directions for thawing and application before use.
Store at –20°C (–4°F) or colder. Unopened pouches may be
stored for up to 48 hours at room temperature (15 – 25°C).
Do not refrigerate or re-freeze.
Rx Only
Contents:
Pre-filled syringe containing:
– Sealer Protein Solution (1): 1 mL, sterile
– Sealer Protein (Human)
– Fibrinolysis Inhibitor (Aprotinin,
Synthetic), 3000 KIU/mL
– Thrombin Solution (2): 1 mL, sterile
– Thrombin (Human), 500 units/mL
– Calcium Chloride, 40 μmol/mL
DMC
Manufactured for
Baxter Healthcare
Corporation
Deerfield, IL 60015 USA
U.S. License No. 140
0736623
Lot No.:
Exp. Date:
P
Tisseel Frozen 2ml Representative Carton Label 1 Of 2 Ndc 0338-8402-02 (Image 03)
Tisseel Frozen 2ml Representative Carton Label 2 Of 2 Ndc 0338-8402-02 (Image 04)
Tisseel Frozen 2 mL Carton Label0736624
Fibrin Sealant
TISSEEL
Vapor Heated, Solvent/Detergent Treated, Frozen
TOPICAL USE ONLY
2 mL
N3 0338-8402-02 3
Fibrin Sealant
TISSEEL
TOPICAL USE ONLY
2 mL
Fibrin Sealant
TISSEEL
Vapor Heated, Solvent/Detergent Treated, Frozen
NDC 0338-8402-02
Prefilled Syringe
2 mL
TOPICAL USE ONLY
Contents:
Pre-filled syringe containing:
Sealer Protein Solution: 1 mL, sterile
– Sealer Protein (Human)
– Fibrinolysis Inhibitor (Aprotinin, Synthetic), 3000 KIU/mL
Thrombin Solution: 1 mL, sterile
– Thrombin (Human), 500 units/mL
– Calcium Chloride, 40 μmol/mL
The risks and benefits of this product should be discussed with the patient.
Rx Only
DO NOT INJECT
Store at –20°C (–4°F) or colder.
Read enclosed directions for thawing and application before use.
Unopened pouches may be stored for up to 48 hours at room
temperature (15 – 25°C).
Do not refrigerate or re-freeze.
Not made with natural rubber latex
For Single Use Only.
Baxter Logo
Fibrin Sealant
TISSEEL
TOPICAL USE ONLY
2 mL
Fibrin Sealant
TISSEEL
TOPICAL USE ONLY
2 mL
Baxter Logo
736624
Fibrin Sealant
TISSEEL
Vapor Heated, Solvent/Detergent Treated, Frozen
Pre-filled Syringe
2 mL
TOPICAL USE ONLY
DO NOT INJECT
U.S. Pat. No.: 5,962,405
Manufactured for Baxter Healthcare Corporation
Deerfield IL, 60015 USA
1-888-229-0001
U.S. License No. 140
Made in Austria
Reorder Number: 1501261
Baxter and Tisseel are trademarks of
Baxter International Inc.
Baxter Logo
Tisseel Lyo 2ml Representative Carton Label 1 Of 2 Ndc 0338-4210-02 (Image 05)
Tisseel Lyo 2ml Representative Carton Label 2 Of 2 Ndc 0338-4210-02 (Image 06)
Tissel Lyo 2 mL Carton LabelNDC 0338-4210-02
Fibrin Sealant
TISSEEL 2 mL
Vapor Heated, Solvent/Detergent Treated, Kit
Baxter Logo
NDC 0338-4210-02
0103033842100284
Fibrin Sealant
TISSEEL 2 mL
Vapor Heated, Solvent/Detergent Treated, Kit
Contents:
Sealer Protein Concentrate (Human), Vapor Heated,
Solvent /Detergent Treated, freeze dried, sterile, for
1 mL of Sealer Protein Solution
Fibrinolysis Inhibitor Solution (Synthetic), sterile,
3000 KIU of Aprotinin /mL
Thrombin (Human), Vapor Heated, Solvent /Detergent
Treated, freeze dried, sterile, for 1 mL of Thrombin
Solution 500 units/mL
Calcium Chloride Solution, sterile, 40 μmol /mL
The risks and benefits of this product should be discussed
with the patient.
Read enclosed directions for reconstitution and application
before use.
Use within four hours of reconstitution.
NOT FOR INJECTION. For single use only.
Not made with natural rubber latex
Rx only
Manufactured for Baxter Healthcare Corporation
Deerfield, IL 60015 USA
U.S. License No. 140
Made in Austria
U.S. Pat. No.: 5,962,405
Baxter and Tisseel are trademarks of Baxter International Inc.
736640
736640
Fibrin Sealant
TISSEEL 2 mL
Vapor Heated, Solvent/
Detergent Treated, Kit
2 mL
Store at 2°C to 25°C (36°F to 77°F).
Avoid freezing.
Tisseel Lyo 2ml Representative Sleeve Label 1 Of 4 Ndc 0338-4301-02 (Image 07)
Tisseel Lyo 2ml Representative Sleeve Label 2 Of 4 Ndc 0338-4301-02 (Image 08)
Tisseel Lyo 2ml Representative Sleeve Label 3 Of 4 Ndc 0338-4301-02 (Image 09)
Tisseel Lyo 2ml Representative Sleeve Label 4 Of 4 Ndc 0338-4301-02 (Image 10)
Tisseel Lyo 2mL Representative Sleeve LabelBaxter Logo
NDC 0338-4301-02
Fibrin Sealant
TISSEEL 2 mL
Vapor Heated, Solvent/Detergent Treated, Kit
Manufactured for Baxter Healthcare Corporation
Deerfield, IL 60015 USA
U.S. License No. 140
Made in Austria
Reorder Number: 1504514
Baxter, Duploject and Tisseel are trademarks of Baxter International Inc.
U.S. Pat. No.: 5,962,405
Baxter Logo
NDC 0338-4301-02
Fibrin Sealant
TISSEEL 2 mL
Vapor Heated, Solvent/Detergent Treated, Kit
TOPICAL USE ONLY
DO NOT INJECT
Baxter Logo
NDC 0338-4301-02
0103033843010230
Fibrin Sealant
TISSEEL 2 mL
Vapor Heated, Solvent/Detergent Treated, Kit
Contents:
Sealer Protein Concentrate (Human), Vapor Heated,
Solvent /Detergent Treated, freeze dried, sterile, for
1 mL of Sealer Protein Solution
Fibrinolysis Inhibitor Solution (Synthetic), sterile,
3000 KIU of Aprotinin /mL
Thrombin (Human), Vapor Heated, Solvent /Detergent
Treated, freeze dried, sterile, for 1 mL of Thrombin Solution
500 units/mL
Calcium Chloride Solution, sterile, 40 μmol /Ml
The risks and benefits of this product should be discussed
with the patient. Read enclosed directions for
reconstitution and application before use. Use within four
hours of reconstitution.
NOT FOR INJECTION. For single use only.
Not made with natural rubber latex
Rx only
0736642
0736642
N3 0338-4301-02 3
Tisseel Frozen 2 mL (4 mL Representative DUO Set Label)
Tisseel Frozen 2 mL – 4 mL DUO Set LabelBaxter Label
DUO Set 2 ml / 4ml
Baxter AG, 1221 Vienna, Austria
0297
LOT
USA
Manufactured for:
Baxter Healthcare Corporation,
Westlake Village, CA 91362 USA
Rx only, single use only, non-pyrogenic
Not made with natural rubber latex
AF082407A04
Tisseel Lyo 2 mL (4 mL DUPLOJET Repesentative Label 1 of 4)
Tisseel Lyo 2 mL (4 mL DUPLOJET Repesentative Label 2 of 4)
Tisseel Lyo 2 mL (4 mL DUPLOJET Repesentative Label 3 of 4)
Tisseel Lyo 2 mL (4 mL DUPLOJET Repesentative Label 4 of 4)
Tisseel Lyo 2 mL - 4 mL DUPLOJET LabelBaxter Logo
DUPLOJET 2 mL / 4 mL
Fibrin Sealant Preparation and
Application System
Baxter Logo
DUPLOJET 2 mL / 4 mL
Fibrin Sealant Preparation and
Application System
BAXTER, DUPLOJET and TISSEEL are trademarks of
Baxter International Inc., registered in the U.S. Patent and
Trademark office.
Manufactured for:
Baxter Healthcare Corporation
Westlake Village, CA 91362 USA
DUPLOJET 2 mL / 4 mL
Fibrin Sealant Preparation and
Application System
For Fibrin Sealant
2 mL or 4 mL Kit
2 mL
4 mL
For the preparation and application of TISSEEL
[Fibrin Sealant] 2 mL / 4 mL Kit.
STERILE – SINGLE PATIENT USE ONLY – DO NOT RESTERILIZE
Use separate devices for reconstruction of Sealer Protein Concentrate
and Thrombin.
Rx only
Made in Austria
000077
M000077
DUPLOJET 2 mL / 4 mL
Fibrin Sealant Preparation and
Application System
For Fibrin Sealant
2 mL or 4 mL Kit
2 mL
4 mL
Duplojet Ifu Representative Label 1 Of 4 (Image 16)
Duplojet Ifu Representative Label 2 Of 4 (Image 17)
Duplojet Ifu Representative Label 3 Of 4 (Image 18)
Duplojet Ifu Representative Label 4 Of 4 (Image 19)
DUPLOJET IFU LabelBaxter Logo
M000239
000239
DUPLOJECT
Fibrin Sealant Preparation and Application System
For the preparation and application of TISSEEL [Fibrin Sealant] kit.
Note: See TISSEEL [Fibrin Sealant] package insert for additional preparation and
application instructions.
1.0 Reconstitution Instructions for the Circulating Nurse (Using the FIBRINO-
THERM Heating and Stirring Device)
1.1 Turn on the warming unit of the FIBRINOTHERM device (amber switch).
1.2 Open TISSEEL [Fibrin Sealant] kit and place all vials into the appropriately sized
heating wells of the FIBRINOTHERM device.
1.3 Place the Sealer Protein vial into the large magnetic stirring well fitted with
the appropriately sized adapter ring (if necessary). Do not activate the stirring
mechanism at this time. The indicator light will remain lit until a temperature of
37°C (98.6°F) is reached. Allow several minutes for proper warming.
1.4 Open Pack A of the DUPLOJECT Preparation and Application System and
assemble the blue-scaled and black-scaled syringes with the needles provided.
1.5 Remove the flip-off caps from the blue-capped Sealer Protein Concentrate
and Fibrinolysis Inhibitor Solution vials and wipe with a non-iodine based dis-
infectant.
1.6 Using the blue-scaled syringe, withdraw the Fibrinolysis Inhibitor Solution from
the vial, tilting the vial slightly to facilitate removal of all solution. Inject the
Fibrinolysis Inhibitor Solution into the Sealer Protein Concentrate vial. Gently
swirl the vial to ensure that the freeze-dried material is fully soaked. Note: Do not
invert or inject air into vials.
1.7 Place the Sealer Protein Concentrate vial in the stirring well and activate the
stirring mechanism of the FIBRINOTHERM device (green switch). Reconstitution
is complete when no undissolved particles are visible. If Sealer Protein is not fully
dissolved after 20 minutes, discard and prepare a fresh kit. Continue with steps 8
through 11.
1.8 Remove the flip-off caps from the black-capped Thrombin and Calcium Chloride
Solution vials and wipe with a non-iodine based disinfectant.
1.9 Using the black-scaled syringe, withdraw the Calcium Chloride Solution from the
vial, tilting the vial slightly to facilitate removal of all solution. Inject the Calcium
Chloride Solution into the Thrombin vial. Note: Do not invert or inject air into vials.
1.10 Swirl contents of the Thrombin vial briefly and return it to an appropriately sized
heating well in the FIBRINOTHERM device.
1.11 Leave the Sealer Protein and Thrombin vials in the FIBRINOTHERM device until
the solutions are ready to be passed into the sterile field.
2.0 Preparation Instructions for the Scrub Nurse
2.1 Open Pack B of the DUPLOJECT Preparation and Application System into the
sterile field.
2.2 Open Packs 1, 2, and 3.
2.3 Assemble the blue-scaled and black-scaled syringes with the needles provided.
Note: For 5 mL DUPLOJECT systems, attach the larger needle to the blue-scaled
syringe.
2.4 While the Circulating Nurse holds the vial slightly tilted, insert needle into
vial (bevel side down) and withdraw all of the Sealer Protein Solution into the
blue-scaled syringe using slow, constant aspiration. Discard needle in sharps
container.
2.5 While the Circulating Nurse holds the vial slightly tilted, insert needle into vial
(bevel side down) and withdraw all of the Thrombin Solution into the black-scaled
syringe using slow, constant aspiration. Discard needle in sharps container.
2.6 Remove any air bubbles from the syringes and ensure both syringes contain the
same volume.
2.7 Snap the filled syringes into the two-syringe clip with the flanges in an up/down
position, as illustrated below.
2.8 Attach the joining piece to the syringe nozzles, ensuring that both are firmly
seated. Secure the joining piece by fastening the retaining strap to the double
syringe clip. Note: Align the syringe nozzles toward the middle for proper
attachment.
2.9 Fit one of the application needles onto the joining piece. A second application
needle is provided in Pack 3 as a spare.
2.10 DUPLOJECT Applicator is ready for use.
2.11 If application of TISSEEL [Fibrin Sealant] is interrupted, replace the needle
immediately before application is resumed. Note: If the apertures of the joining
piece become clogged, Pack 4 contains one spare joining piece and two
additional application needles.
Rx Only
DO NOT REUSE OR RESTERILIZE.
DISPOSE OF CONTAMINATED AND SHARP COMPONENTS PROPERLY.
BAXTER, DUPLOJECT, FIBRINOTHERM and TISSEEL are trademarks of Baxter International Inc.,
registered in the U.S. Patent and Trademark Office.
Baxter Healthcare Corporation
Westlake Village, CA 91362 USA