5.1 Hypersensitivity to CORTROSYN Injection
CORTROSYN injection hypersensitivity reactions including anaphylaxis have been reported. Monitor patients for hypersensitivity reactions and treat as needed.
5.2 Diagnostic Inaccuracies
Cortisol levels and subsequent diagnosis of adrenocortical insufficiency following CORTROSYN administration may be inaccurate if patients are on certain medications because of their effect on cortisol or cortisol binding globulin levels.
Glucocorticoids and spironolactone may result in falsely elevated cortisol levels. Stop these drugs on the day of CORTROSYN testing. Long-acting glucocorticoids may need to be stopped for a longer period before CORTROSYN testing [see Dosage and Administration (2.1) and Drug Interactions (7)].
Estrogen-containing drugs increase cortisol binding globulin levels which can increase plasma total cortisol levels. To obtain accurate plasma total cortisol levels, stop estrogen containing drugs four to six weeks before CORTROSYN testing to allow cortisol binding globulin levels to return to levels within the reference range [see Dosage and Administration (2.1) and Drug Interactions (7)]. Alternatively, concomitant measurement of cortisol binding globulin at the time of testing can be done; if cortisol binding globulin levels are elevated, plasma total cortisol levels are considered inaccurate.
Any condition that elevates or lowers cortisol binding globulin levels may increase or decrease plasma total cortisol levels, respectively. Cortisol binding globulin levels can be low in cirrhosis or nephrotic syndrome. Measure cortisol binding globulin levels as necessary to ensure accuracy of interpretation of plasma total cortisol levels.