- Home
- Labeler Index
- Hospira, Inc.
- 0409-1610
- FDA Recall: Marcaine
FDA Recall Marcaine
View Recall Number, Date, Reasons, Quantity
FDA Recall Enforcement Reports
The last Recall Enforcement Report for Marcaine with NDC 0409-1610 was initiated on 09-16-2016 as a Class II recall due to lack of assurance of sterility and subpotent drug: defect in glass vial prevented stopper from forming a seal allowing water to ingress and dilute the product causing it to be less than the labeled potency. The latest recall number for this product is D-0097-2017 and the recall is currently terminated as of 07-31-2019 .
Recall Number | Initiation Date | Report Date | Recall Classification | Product Quantity | Product Description | Status |
---|---|---|---|---|---|---|
D-0097-2017 | 09-16-2016 | 10-19-2016 | Class II | 4768 vials | Marcaine 0.5% (bupivacaine HCl) injection, USP, 250 mg/50 mL (5 mg/mL), 50 mL Multiple-Dose Vial, Rx only, Hospira, Inc., Lake Forest, IL 60045, NDC 0409-1610-50. | Terminated |
D-0096-2017 | 09-16-2016 | 10-19-2016 | Class II | 15 vials | Marcaine 0.25% (bupivacaine HCl) injection, USP, 125 mg/50 mL (2.5 mg/mL), 50 mL Multiple-Dose Vial, Rx only, Hospira, Inc., Lake Forest, IL 60045, NDC 0409-1587-50. | Terminated |
D-0002-2015 | 06-17-2014 | 10-08-2014 | Class I | 40,730 vials | Marcaine (bupivacaine HCl) injection, USP, 0.5%, Preservative-Free, 30 mL (150 mg) Single-dose Vial, Rx only, Hospira, Inc., Lake Forest, IL 60045 NDC 0409-1560-29 | Terminated |
D-1358-2014 | 04-21-2014 | 06-11-2014 | Class I | 85,680 vials | Marcaine (bupivacaine HCl) injection, USP, 0.25%, Preservative-Free, 10 mL (25 mg) Single-dose Vial, Rx only, Hospira, Inc., Lake Forest, IL 60045 USP, NDC 0409-1559-10. | Terminated |
D-1161-2014 | 10-18-2013 | 03-26-2014 | Class I | 40,360 vials | Marcaine (bupivacaine HCl) injection, USP, 0.25%, 30 mL single-dose vials-preservative free, packaged in 10-count vials per carton, Rx only, Hospira, Inc., Lake Forest, IL 60045, NDC 0409-1559-30. | Terminated |
What is the Enforcement Report?
All drug recalls are monitored by the Food and Drug Administration (FDA) and are included in the Enforcement Report once they are properly classified. The FDA will determine if a firm's removal or correction actions of a marked product meet the requirements to be considered a "recall". The FDA will also determine the public hazard assessment and a recall classification will be published in the Enforcement Report.
Recall Enforcement Report D-0097-2017
- Event ID
- 75156 What is the Event ID?
A numerical designation assigned by FDA to a specific recall event (used for tracking purposes). - Recall Number
- D-0097-2017 What is the Recall Number?
An alphanumeric designation assigned by FDA to a specific, classified recalled product (used for tracking purposes). - Recall Classification
- Class II - is a situation in which use of, or exposure to, a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote What is the Recall Classification?
Numerical designation (I, II, or III) that is assigned by FDA to a particular product recall that indicates the relative degree of health hazard. For recalls pending classification, the entry will display as "Not Yet Classified". - Distribution Pattern
- Nationwide and Puerto Rico What is the Distribution Pattern?
General area of initial distribution such as states, countries, or territories. Note that subsequent distribution by the consignees to other parties may not be included. - Product Description
- Marcaine 0.5% (bupivacaine HCl) injection, USP, 250 mg/50 mL (5 mg/mL), 50 mL Multiple-Dose Vial, Rx only, Hospira, Inc., Lake Forest, IL 60045, NDC 0409-1610-50.
- Reason For Recall
- Lack of Assurance of Sterility and Subpotent Drug: defect in glass vial prevented stopper from forming a seal allowing water to ingress and dilute the product causing it to be less than the labeled potency. What is the Reason for Recall?
Information describing how the product is defective. - Product Quantity
- 4768 vials Product Quantity
The amount of product subject to recall. - Voluntary Mandated
- Voluntary: Firm initiated Voluntary / Mandated
Designates that a recall was initiated voluntarily by a firm on its own volition or after being requested to recall by FDA. "Mandatory" designates that a recall was initiated under a mandatory (statutory) recall authority, a court order, or FDA order. - Report Date
- 10-19-2016
- Recall Initiation Date
- 09-16-2016 What is the Recall Initiation Date?
The date that the firm first began notifying the public or their consignees of the recall. - Termination Date
- 07-31-2019 What is the Date Terminated?
The date that FDA terminated the recall. - Initial Firm Notification
- Letter Initial Firm Notification of Consignee or Public
The method(s) by which the firm initially notified the public or their consignees of a recall. - Product Type
- Drugs
- Recalling Firm
- Hospira Inc., A Pfizer Company
- Code Info
- Lot #: 59310DD, Exp 1NOV2017 Code Information
A list of all lot and/or serial numbers, product numbers, expiration dates, sell or use by dates, etc., which appear on the product or its labeling. - Recalled NDC Packages
- 0409-1559-18; 0409-1559-10; 0409-1559-19; 0409-1559-30; 0409-1560-18; 0409-1560-10; 0409-1560-19; 0409-1560-29; 0409-1582-18; 0409-1582-10; 0409-1582-19; 0409-1582-29; 0409-1587-50; 0409-1610-50; 0409-1746-70; 0409-1746-10; 0409-1746-71; 0409-1746-30; 0409-1749-70; 0409-1749-10; 0409-1749-71; 0409-1749-29; 0409-1752-50; 0409-1755-50
- Status
- Terminated - A recall where FDA has determined that all reasonable efforts have been made to remove or correct the violative product in accordance with the recall strategy, and proper disposition has been made according to the degree of hazard.
Recall Enforcement Report D-0096-2017
- Event ID
- 75156 What is the Event ID?
A numerical designation assigned by FDA to a specific recall event (used for tracking purposes). - Recall Number
- D-0096-2017 What is the Recall Number?
An alphanumeric designation assigned by FDA to a specific, classified recalled product (used for tracking purposes). - Recall Classification
- Class II - is a situation in which use of, or exposure to, a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote What is the Recall Classification?
Numerical designation (I, II, or III) that is assigned by FDA to a particular product recall that indicates the relative degree of health hazard. For recalls pending classification, the entry will display as "Not Yet Classified". - Distribution Pattern
- Nationwide and Puerto Rico What is the Distribution Pattern?
General area of initial distribution such as states, countries, or territories. Note that subsequent distribution by the consignees to other parties may not be included. - Product Description
- Marcaine 0.25% (bupivacaine HCl) injection, USP, 125 mg/50 mL (2.5 mg/mL), 50 mL Multiple-Dose Vial, Rx only, Hospira, Inc., Lake Forest, IL 60045, NDC 0409-1587-50.
- Reason For Recall
- Lack of Assurance of Sterility and Subpotent Drug: defect in glass vial prevented stopper from forming a seal allowing water to ingress and dilute the product causing it to be less than the labeled potency. What is the Reason for Recall?
Information describing how the product is defective. - Product Quantity
- 15 vials Product Quantity
The amount of product subject to recall. - Voluntary Mandated
- Voluntary: Firm initiated Voluntary / Mandated
Designates that a recall was initiated voluntarily by a firm on its own volition or after being requested to recall by FDA. "Mandatory" designates that a recall was initiated under a mandatory (statutory) recall authority, a court order, or FDA order. - Report Date
- 10-19-2016
- Recall Initiation Date
- 09-16-2016 What is the Recall Initiation Date?
The date that the firm first began notifying the public or their consignees of the recall. - Termination Date
- 07-31-2019 What is the Date Terminated?
The date that FDA terminated the recall. - Initial Firm Notification
- Letter Initial Firm Notification of Consignee or Public
The method(s) by which the firm initially notified the public or their consignees of a recall. - Product Type
- Drugs
- Recalling Firm
- Hospira Inc., A Pfizer Company
- Code Info
- Lot #: 60295DD, Ep 1DEC2017 Code Information
A list of all lot and/or serial numbers, product numbers, expiration dates, sell or use by dates, etc., which appear on the product or its labeling. - Recalled NDC Packages
- 0409-1559-18; 0409-1559-10; 0409-1559-19; 0409-1559-30; 0409-1560-18; 0409-1560-10; 0409-1560-19; 0409-1560-29; 0409-1582-18; 0409-1582-10; 0409-1582-19; 0409-1582-29; 0409-1587-50; 0409-1610-50; 0409-1746-70; 0409-1746-10; 0409-1746-71; 0409-1746-30; 0409-1749-70; 0409-1749-10; 0409-1749-71; 0409-1749-29; 0409-1752-50; 0409-1755-50
- Status
- Terminated - A recall where FDA has determined that all reasonable efforts have been made to remove or correct the violative product in accordance with the recall strategy, and proper disposition has been made according to the degree of hazard.
Recall Enforcement Report D-0002-2015
- Event ID
- 68579 What is the Event ID?
A numerical designation assigned by FDA to a specific recall event (used for tracking purposes). - Recall Number
- D-0002-2015 What is the Recall Number?
An alphanumeric designation assigned by FDA to a specific, classified recalled product (used for tracking purposes). - Recall Classification
- Class I - is a situation in which there is a reasonable probability that the use of, or exposure to, a violative product will cause serious adverse health consequences or death. What is the Recall Classification?
Numerical designation (I, II, or III) that is assigned by FDA to a particular product recall that indicates the relative degree of health hazard. For recalls pending classification, the entry will display as "Not Yet Classified". - Distribution Pattern
- Nationwide What is the Distribution Pattern?
General area of initial distribution such as states, countries, or territories. Note that subsequent distribution by the consignees to other parties may not be included. - Product Description
- Marcaine (bupivacaine HCl) injection, USP, 0.5%, Preservative-Free, 30 mL (150 mg) Single-dose Vial, Rx only, Hospira, Inc., Lake Forest, IL 60045 NDC 0409-1560-29
- Reason For Recall
- Presence of Particulate Matter: Confirmed customer complaint of discolored solution with visible metal particles embedded in the glass vial and visible in the solution. What is the Reason for Recall?
Information describing how the product is defective. - Product Quantity
- 40,730 vials Product Quantity
The amount of product subject to recall. - Voluntary Mandated
- Voluntary: Firm Initiated Voluntary / Mandated
Designates that a recall was initiated voluntarily by a firm on its own volition or after being requested to recall by FDA. "Mandatory" designates that a recall was initiated under a mandatory (statutory) recall authority, a court order, or FDA order. - Report Date
- 10-08-2014
- Recall Initiation Date
- 06-17-2014 What is the Recall Initiation Date?
The date that the firm first began notifying the public or their consignees of the recall. - Termination Date
- 04-03-2017 What is the Date Terminated?
The date that FDA terminated the recall. - Initial Firm Notification
- Press Release Initial Firm Notification of Consignee or Public
The method(s) by which the firm initially notified the public or their consignees of a recall. - Product Type
- Drugs
- Recalling Firm
- Hospira Inc.
- Code Info
- Lot # 33-545-DD, Exp. 09/15 Code Information
A list of all lot and/or serial numbers, product numbers, expiration dates, sell or use by dates, etc., which appear on the product or its labeling. - Recalled NDC Packages
- 0409-1559-18; 0409-1559-10; 0409-1559-19; 0409-1559-30; 0409-1560-18; 0409-1560-10; 0409-1560-19; 0409-1560-29; 0409-1582-18; 0409-1582-10; 0409-1582-19; 0409-1582-29; 0409-1587-50; 0409-1610-50; 0409-1746-70; 0409-1746-10; 0409-1746-71; 0409-1746-30; 0409-1749-70; 0409-1749-10; 0409-1749-71; 0409-1749-29; 0409-1752-50; 0409-1755-50
- Status
- Terminated - A recall where FDA has determined that all reasonable efforts have been made to remove or correct the violative product in accordance with the recall strategy, and proper disposition has been made according to the degree of hazard.
Recall Enforcement Report D-1358-2014
- Event ID
- 68048 What is the Event ID?
A numerical designation assigned by FDA to a specific recall event (used for tracking purposes). - Recall Number
- D-1358-2014 What is the Recall Number?
An alphanumeric designation assigned by FDA to a specific, classified recalled product (used for tracking purposes). - Recall Classification
- Class I - is a situation in which there is a reasonable probability that the use of, or exposure to, a violative product will cause serious adverse health consequences or death. What is the Recall Classification?
Numerical designation (I, II, or III) that is assigned by FDA to a particular product recall that indicates the relative degree of health hazard. For recalls pending classification, the entry will display as "Not Yet Classified". - Distribution Pattern
- Nationwide. What is the Distribution Pattern?
General area of initial distribution such as states, countries, or territories. Note that subsequent distribution by the consignees to other parties may not be included. - Product Description
- Marcaine (bupivacaine HCl) injection, USP, 0.25%, Preservative-Free, 10 mL (25 mg) Single-dose Vial, Rx only, Hospira, Inc., Lake Forest, IL 60045 USP, NDC 0409-1559-10.
- Reason For Recall
- Presence of Particulate Matter: Confirmed customer complaint of discolored solution with visible metal particles embedded in the glass vial and visible in the solution. What is the Reason for Recall?
Information describing how the product is defective. - Product Quantity
- 85,680 vials Product Quantity
The amount of product subject to recall. - Voluntary Mandated
- Voluntary: Firm initiated Voluntary / Mandated
Designates that a recall was initiated voluntarily by a firm on its own volition or after being requested to recall by FDA. "Mandatory" designates that a recall was initiated under a mandatory (statutory) recall authority, a court order, or FDA order. - Report Date
- 06-11-2014
- Recall Initiation Date
- 04-21-2014 What is the Recall Initiation Date?
The date that the firm first began notifying the public or their consignees of the recall. - Termination Date
- 03-16-2017 What is the Date Terminated?
The date that FDA terminated the recall. - Initial Firm Notification
- Press Release Initial Firm Notification of Consignee or Public
The method(s) by which the firm initially notified the public or their consignees of a recall. - Product Type
- Drugs
- Recalling Firm
- Hospira Inc.
- Code Info
- Lot #: 34-440-DD, Exp 10/15 Code Information
A list of all lot and/or serial numbers, product numbers, expiration dates, sell or use by dates, etc., which appear on the product or its labeling. - Recalled NDC Packages
- 0409-1559-18; 0409-1559-10; 0409-1559-19; 0409-1559-30; 0409-1560-18; 0409-1560-10; 0409-1560-19; 0409-1560-29; 0409-1582-18; 0409-1582-10; 0409-1582-19; 0409-1582-29; 0409-1587-50; 0409-1610-50; 0409-1746-70; 0409-1746-10; 0409-1746-71; 0409-1746-30; 0409-1749-70; 0409-1749-10; 0409-1749-71; 0409-1749-29; 0409-1752-50; 0409-1755-50
- Status
- Terminated - A recall where FDA has determined that all reasonable efforts have been made to remove or correct the violative product in accordance with the recall strategy, and proper disposition has been made according to the degree of hazard.
Recall Enforcement Report D-1161-2014
- Event ID
- 66503 What is the Event ID?
A numerical designation assigned by FDA to a specific recall event (used for tracking purposes). - Recall Number
- D-1161-2014 What is the Recall Number?
An alphanumeric designation assigned by FDA to a specific, classified recalled product (used for tracking purposes). - Recall Classification
- Class I - is a situation in which there is a reasonable probability that the use of, or exposure to, a violative product will cause serious adverse health consequences or death. What is the Recall Classification?
Numerical designation (I, II, or III) that is assigned by FDA to a particular product recall that indicates the relative degree of health hazard. For recalls pending classification, the entry will display as "Not Yet Classified". - Distribution Pattern
- Nationwide What is the Distribution Pattern?
General area of initial distribution such as states, countries, or territories. Note that subsequent distribution by the consignees to other parties may not be included. - Product Description
- Marcaine (bupivacaine HCl) injection, USP, 0.25%, 30 mL single-dose vials-preservative free, packaged in 10-count vials per carton, Rx only, Hospira, Inc., Lake Forest, IL 60045, NDC 0409-1559-30.
- Reason For Recall
- Presence of Particulate Matter: Units of this lot may have visible metal particles embedded in the vial and in the solution causing the product to be discolored. What is the Reason for Recall?
Information describing how the product is defective. - Product Quantity
- 40,360 vials Product Quantity
The amount of product subject to recall. - Voluntary Mandated
- Voluntary: Firm initiated Voluntary / Mandated
Designates that a recall was initiated voluntarily by a firm on its own volition or after being requested to recall by FDA. "Mandatory" designates that a recall was initiated under a mandatory (statutory) recall authority, a court order, or FDA order. - Report Date
- 03-26-2014
- Recall Initiation Date
- 10-18-2013 What is the Recall Initiation Date?
The date that the firm first began notifying the public or their consignees of the recall. - Termination Date
- 12-18-2015 What is the Date Terminated?
The date that FDA terminated the recall. - Initial Firm Notification
- Letter Initial Firm Notification of Consignee or Public
The method(s) by which the firm initially notified the public or their consignees of a recall. - Product Type
- Drugs
- Recalling Firm
- Hospira Inc.
- Code Info
- Lot 25-220-DD, Exp 1JAN2015 Code Information
A list of all lot and/or serial numbers, product numbers, expiration dates, sell or use by dates, etc., which appear on the product or its labeling. - Recalled NDC Packages
- 0409-1559-18; 0409-1559-10; 0409-1559-19; 0409-1559-30; 0409-1560-18; 0409-1560-10; 0409-1560-19; 0409-1560-29; 0409-1582-18; 0409-1582-10; 0409-1582-19; 0409-1582-29; 0409-1587-50; 0409-1610-50; 0409-1746-70; 0409-1746-10; 0409-1746-71; 0409-1746-30; 0409-1749-70; 0409-1749-10; 0409-1749-71; 0409-1749-29; 0409-1752-50; 0409-1755-50
- Status
- Terminated - A recall where FDA has determined that all reasonable efforts have been made to remove or correct the violative product in accordance with the recall strategy, and proper disposition has been made according to the degree of hazard.