Cpda-1 Solution
Product Images NDC 0942-6305

5 FDA label images from Fenwal, Inc. · Packaging, Regulatory Labels, and Product Appearance

Product Visual Gallery

This gallery contains 5 technical images submitted to the FDA as part of the official labeling for Cpda-1 (NDC 0942-6305). Unlike standard consumer photos, these assets often include clinical data figures, molecular chemical structures, and official manufacturer packaging layouts.

As provided by Fenwal, Inc., these visuals offer a comprehensive scientific overview of the product's physical and chemical identity, aiding pharmacists and researchers in product verification and study.

FDA Label Image

Anticoagulant Citrate Phosphate Dextrose Adenine Solution, Usp (cpda-1) Blood-pack™ Unit Label (Bb15753f Ec9d 4fa5 B63b 7d3b429ba031 05)

Anticoagulant Citrate Phosphate Dextrose Adenine Solution, Usp (cpda-1) Blood-pack™ Unit Label (Bb15753f Ec9d 4fa5 B63b 7d3b429ba031 05)
The label for Fenwal Blood-Pack Unit Triple features Anticoagulant Citrate Phosphate Dextrose Adenine Solution, USP (CPDA-1). It is intended for collection and processing of 450 mL blood with 63 mL solution. Lists ingredients with specific strengths, manufacturer Fresenius Kabi AG (Germany), and storage instructions. Includes barcode and handling notes.*
FDA Label Image

Export 00

Export 00
Instructional diagram showing centrifuge cup loading steps for a Blood-Pack unit (BPU) without filter. It includes folding and arranging satellite containers with the Y-connector, using a Sorvall Blood Bag Insert, placing the bundle into the centrifuge cup, pressing down the containers, and confirming proper positioning of the cannula and components before centrifugation.*
FDA Label Image

Export 01

Export 01
A symbols definitions panel explaining icons related to product usage and handling. It includes cautions, sterilization by steam, non-pyrogenic fluid path, do not reuse, do not vent, orientation arrows, lot, and reference code symbols.*
FDA Label Image

Export 02

Export 02
Representative product drawing and photographs illustrating the CPDA-1 anticoagulant intravenous solution's sampling system and container setup. Figures include labeled line diagrams of the primary container, optional satellite containers, and sampling system with donor needle, breakaway cannula, Y-junction, blue clamp, sample pouch, and sampling site, along with photos showing the cannula on an arm and a syringe drawing blood from the sampling site.*
FDA Label Image

Export 03

Export 03
A series of figures and a drawing related to CPDA-1 administration and sampling. Figure 1 is a labeled diagram showing a breakaway cannula, Y-junction, donor needle, blue clamp, sampling site, and sample pouch. Figure 2 is a photo of a wrapped IV line on a patient's arm. Figure 3 shows a gloved hand drawing fluid from the IV line with a syringe. Below these, a representative product drawing depicts three containers (primary, satellite, and optional satellite) connected by tubing and a sampling system including a needle.*

* About these descriptions: Image descriptions on this page are generated by automated AI analysis of the product label images from the manufacturer's FDA label submission (SPL). They are provided for reference only and may contain errors or omissions. Always rely on the printed label itself and the official FDA labeling, and consult a pharmacist or healthcare professional with any questions about this product.