Cpda-1 Solution
Product Images NDC 0942-6312

View Photos of Packaging, Regulatory Labels, and Product Appearance

Product Visual Gallery

This gallery contains 4 technical images submitted to the FDA as part of the official labeling for Cpda-1 (NDC 0942-6312). Unlike standard consumer photos, these assets often include clinical data figures, molecular chemical structures, and official manufacturer packaging layouts.

As provided by Fenwal, Inc., these visuals offer a comprehensive scientific overview of the product's physical and chemical identity, aiding pharmacists and researchers in product verification and study.

FDA Label Image

Anticoagulant Citrate Phosphate Dextrose Adenine Solution, Usp (cpda-1) Blood-pack™ Unit Label (7664c2b2 9088 414c 93b8 28924a076a9a 05)

Anticoagulant Citrate Phosphate Dextrose Adenine Solution, Usp (cpda-1) Blood-pack™ Unit Label (7664c2b2 9088 414c 93b8 28924a076a9a 05)
This is the description of a blood pack unit with code 4R3644 designed for collection and processing of 500 mL Blood. It comes with an anticoagulant solution called CPDA-1 and a 16 ga. Ultra Thin Wall Fenwal HighFlo Needle. Each unit has a primary container with 70 mL of solution and three empty 400 mL Transfer Pack containers. The solution contains Adenine, Citrate Phosphate Dextrose, and sodium hydroxide. The unit is sterile and non-pyrogenic and should be used only once, with instructions for use. It should be stored at Controlled Room Temperature, avoiding freezing or excessive heat. The unit comes in a pouch to be opened by tearing across the notch. After opening the pouch, unused units in the open pouch can be kept for up to 60 days by folding and securing the open end of the pouch. The manufacturer is Fresenlus Kabl AG in Germany.*
FDA Label Image

Export 00

Export 00
This document provides instructions on how to load centrifuge cups for a BPU without a filter, including separate containers taped together with Adsol container on top. The containers should be placed horizontally with tubing facing outwards and the V-connector at the top. Additionally, oval blood bags are recommended to prevent overexpansion and potential breakage. Proper stacking order can vary depending on equipment and should comply with facility SOPs. Precautions and warnings should be noted before use.*
FDA Label Image

Export 01

FDA Label Image

Export 02

Export 02
The text describes a product drawing of a sampling system with a Y-junction, blue clamp, and donor and sample pouch containers. The drawing also includes a surging system and needles. However, the quality of the text is poor, and some words are not readable.*

* These product label images have been analyzed using experimental machine learning. Please verify findings with the primary label text.