Product Images Adsol Red Cell Preservation
View Photos of Packaging, Labels & Appearance
Product Label Images
The following 5 images provide visual information about the product associated with Adsol Red Cell Preservation NDC 0942-6516 by Fenwal, Inc., such as packaging, labeling, and the appearance of the drug itself. This resource could be helpful for medical professionals, pharmacists, and patients seeking to verify medication information and ensure they have the correct product.
6R1784lbl - export 00

This is a description of Anticoagulant Citrate Phosphate Dextrose Solution, USP (CPD) Blood-Pack for the collection and processing of 500 mL Blood. The unit has Transfer-Pack Container with Adsol Red Cell Preservation Solution, Integral Fenwal Bioflex RC Red Cell Leukocyte Reduction Filter, and Y-Sampling Site. It also contains Fenwal HighFlo Needle and should be stored at a controlled room temperature to protect it from freezing and excessive heat. The manufacturer is Fresenius Kabi AG, located in Germany, and the Manufacturing facility is Fenwal International, Inc., located in Maricao, Puerto Rico. The text includes instructions for opening the package, handling, storage, and disposal.*
17821784OptA - image 02

This is a set of instructions for loading containers into a centrifuge cup. It begins with arranging the containers with their bottoms facing the same direction. The BlooPack container stacking order is described, as well as the proper alignment for the containers. The instructions also provide precautions when handling the Adsol cannula and notes on how to ensure the folded satelite containers do not interfere with the centrifugation process. The user must avoid placing the tubing near the bottom of the container and perform the centrifugation following center procedures.*
17821784OptB - image 03

These are instructions for loading a centrifuge cup using the "Large Oval Cup Method" and "Option B." First, a workspace must be prepared, and the containers should be arranged with their bottoms facing the same direction. The primary container, Adsol container, filter, tubing, and empty satellite containers are stacked in that order. Precautions should be taken when handling the Adsol cannula and not pressing it directly. The containers should be squeezed on the sides and slid into the centrifuge cup, taking care not to pre-activate the cannulae. The top of the Adsol container should be folded over, and the excess tubing is pushed down onto the centrifuge cup. The cup is then centrifuged according to standard procedures.*
17821784lblsymbols - image 05

This is a warning message for a product that has been sterilized using steam and has a sterile fluid path that is non-pyrogenic. It is important to consult the instructions for use and not to reuse the product. Additionally, it should not be used if the sterile barrier system of the product is compromised.*
* The product label images have been analyzed using a combination of traditional computing and machine learning techniques. It should be noted that the descriptions provided may not be entirely accurate as they are experimental in nature. Use the information in this page at your own discretion and risk.