Product Images Fludeoxyglucose F18

View Photos of Packaging, Labels & Appearance

Product Label Images

The following 5 images provide visual information about the product associated with Fludeoxyglucose F18 NDC 76451-118 by 3d Imaging Drug Design And Development Llc, such as packaging, labeling, and the appearance of the drug itself. This resource could be helpful for medical professionals, pharmacists, and patients seeking to verify medication information and ensure they have the correct product.

Inner Label, ALL vials and syringes - InnerAll

Inner Label, ALL vials and syringes - InnerAll

Outer label 10 mL Syringe - Syringe10FDGOuter

Outer label 10 mL Syringe - Syringe10FDGOuter

This is a description of a fludeoxyglucose F18 injection supplied in a single-dose 10mL syringe. It is a sterile, non-pyrogenic diagnostic for intravenous use only. The injection contains 0.74 GBq to 11.1 GBq (20 mCi to 300 mCi) /ml of no carrier added Fludeoxyglucose F 18 with a concentration of 20 mCi/mlL and volume 1.5mL. The calibration (EOS*) date and time is 8-3-13 10:30 am with an expiration period of 12 hours after EOS. It is important to use the injection within 12 hours of EOS and calculate the correct dosage from the date and time of calibration. The injection should be stored upright in a shielded container at 25°C (77°F) and not used if cloudy or contains particulate matter. The product has a half-life of 109.7 minutes. It has been manufactured by 3D Imaging, Little Rock, AR 72205. Radioactive material Rx only.*

Outer label 5 mL Syringe - Syringe5FDGOuter

Outer label 5 mL Syringe - Syringe5FDGOuter

This is a description of a single-dose 5ml syringe containing fludeoxyglucose F18 injection, a sterile and non-pyrogenic diagnostic intended solely for intravenous use. The 1.5ml solution has a concentration of 20mCi/mlL, which should be used within 12 hours of the calibration date and time to ensure efficacy. The EOS calibration was done with 30mCi of total activity, on 8-3-13 at 10:30 am. The solution contains no carrier added Fludeoxyglucose F 18, ranging from 0.74GBq to 11.1GBq (20mCi to 300mCi) /mL. It is imperative to handle doses aseptically and keep in a shielded container at 25°C (77°F), away from direct sunlight. The half-life of the solution is 109.7 minutes. A lot number labeled 1308030702 is also included. The manufacturer of the solution is 3D Imaging located in Little Rock, AR 72205.*

Outer label 10 mL Vial - Vial10FDGOuter

Outer label 10 mL Vial - Vial10FDGOuter

This is a description of a Multi-Dose Fludeoxyglucose F18 Injection for diagnostic intravenous use. The concentration of the injection is 100 mCi/mL, and the volume is 4 ml. The Lot number is 1308030702, and the calibration date and time is 8-3-13 10:30 am. Its total activity is 400 mCi, and it contains no carrier added Fludeoxyglucose F18 ranging from 0.74 GBq to 11.1 GBq (20 mCi to 300 mCi) /mL. This injection expires 12 hours after End of Synthesis (EOS), which is 8-3-13 10:30 pm, and should be used before then. The correct dosage should be calculated from date and time of calibration. It is sterile, non-pyrogenic, and must be stored at 25°C (77°F) upright in a shielded container. The Half-life of the injection is 109.7 min. It should not be used if cloudy or containing particulate matter. This is a radioactive material, RX only. The manufacturer is 3D Imaging, located in Little Rock, AR 72205, and you can reach them at 501-526-5550 or [email protected] for orders.*

Outer label 30 mL Vial - Vial30FDGOuter

Outer label 30 mL Vial - Vial30FDGOuter

This is information about Fludeoxyglucose F18 Injection, which is a sterile and non-pyrogenic diagnostic solution meant for intravenous use only. The packaging includes a multi-dose 30 mL vial with a concentration of 100 mCi/mL and volume of 4 mL. This substance contains between 0.74 GBq to 11.1 GBq (20 mCi to 300 mCi) /mL of no carrier added Fludeoxyglucose F 18. The solution's calibration date and time should be calculated from the end of synthesis (EOS). This product can only be used within 12 hours of EOS and should be stored at 25°C (77°F) upright and in a shielded container. Any dosage calculation should be calculated from the date and time of calibration. Be cautious to not use this medical product if it's cloudy or includes particulate matter.*

* The product label images have been analyzed using a combination of traditional computing and machine learning techniques. It should be noted that the descriptions provided may not be entirely accurate as they are experimental in nature. Use the information in this page at your own discretion and risk.