Miudella Intrauterine Device
Product Images NDC 78206-210

View Photos of Packaging, Regulatory Labels, and Product Appearance

Product Visual Gallery

This gallery contains 21 technical images submitted to the FDA as part of the official labeling for Miudella (NDC 78206-210). Unlike standard consumer photos, these assets often include clinical data figures, molecular chemical structures, and official manufacturer packaging layouts.

As provided by Organon Llc, these visuals offer a comprehensive scientific overview of the product's physical and chemical identity, aiding pharmacists and researchers in product verification and study.

FDA Label Image

Figure A (Miudella 01)

Figure A (Miudella 01)
Illustration of the Miudella 175 mm intrauterine device insertion instrument showing top and side views. Components identified include the pre-loaded Miudella device, uterine depth markings, flange, insertion tube, handle with position markings, slider, and end cap, highlighting parts relevant for intrauterine placement.*
FDA Label Image

Figure B (Miudella 02)

Figure B (Miudella 02)
Illustration of the Miudella intrauterine device made of a nitinol frame with copper sleeves and retrieval threads. The device dimensions are approximately 32 mm in width and 30 mm in height, with detailed labels identifying the copper sleeves and retrieval threads.*
FDA Label Image

Image (Miudella 03)

Image (Miudella 03)
An instructional illustration showing a pair of gloved hands opening the lid of a package containing a Miudella 175 mm intrauterine device (IUD). A close-up highlights the indicated spot to open the lid, labeled 'Open Here,' with an arrow showing the lid being lifted.*
FDA Label Image

Image (Miudella 04)

Image (Miudella 04)
An instructional illustration showing hands removing a paper lid from the packaging of the Miudella intrauterine device (IUD). The diagram highlights the flange in the notch of the package, guiding proper handling during device removal.*
FDA Label Image

Image (Miudella 05)

Image (Miudella 05)
An instructional illustration showing how to remove the Miudella intrauterine device from its package. It depicts gloved hands lifting the paper lid, positioning the flange in a notch, and keeping a finger on the slider while lifting the handle out of the package.*
FDA Label Image

Image (Miudella 06)

Image (Miudella 06)
An instructional illustration depicting the Miudella intrauterine device (IUD) insertion tool and the IUD itself, focusing on correctly positioning the Miudella device within the uterus. The diagram includes a close-up view highlighting the device and an eye symbol indicating line of sight during insertion.*
FDA Label Image

Image (Miudella 07)

Image (Miudella 07)
Illustration diagram showing the insertion of the Miudella Copper intrauterine device (IUD). The image demonstrates advancing the inserter containing the IUD to the uterine fundus, highlighting proper placement technique with directional arrows and labeled parts.*
FDA Label Image

Image (Miudella 08)

Image (Miudella 08)
Illustration showing the intrauterine device (IUD) Miudella being positioned and pulled back 1-2 cm from the uterine fundus. The device is depicted inside a uterus diagram, with an arrow indicating the direction to pull the IUD slightly downward for correct placement.*
FDA Label Image

Image (Miudella 09)

Image (Miudella 09)
Illustration showing the insertion of an intrauterine device (IUD) named Miudella, a copper IUD. The diagram depicts positioning the device correctly inside the uterus and a hand operating the insertion tool with an indication of a 'click' sound at position 1, guiding proper placement.*
FDA Label Image

Image (Miudella 10)

Image (Miudella 10)
An instructional diagram illustrating the proper insertion and holding position of the Miudella copper intrauterine device (IUD) during placement. The images show the device being inserted into the uterus with an arrow indicating the direction and a hand holding the device handle to maintain position.*
FDA Label Image

Image (Miudella 11)

Image (Miudella 11)
An instructional diagram showing the intrauterine placement of the Miudella copper intrauterine device (IUD) inside the uterus. The illustration also depicts a close-up of the device being held and adjusted to position 2 with an indicated "Click" sound, demonstrating part of the insertion or positioning process.*
FDA Label Image

Image (Miudella 12)

Image (Miudella 12)
An instructional diagram showing hands holding a Miudella intrauterine device (IUD) applicator, demonstrating how to twist the end cap 1/2 to 3/4 turn to the left. The diagram includes a close-up of the end cap labeled with a "Twist 3" arrow indicating the direction and amount to turn.*
FDA Label Image

Image (Miudella 13)

Image (Miudella 13)
An instructional illustration showing hands removing the end cap from a Miudella copper intrauterine device (IUD) applicator prior to insertion. The close-up highlights the numbered green end cap labeled with '3' facilitating proper device preparation.*
FDA Label Image

Image (Miudella 14)

Image (Miudella 14)
An instructional illustration showing hands holding a contraceptive intrauterine device (IUD) inserter. The diagram highlights pulling the release thread free from the inserter, with labels indicating the 'End of release thread' and an arrow pointing downward to the release action.*
FDA Label Image

Image (Miudella 15)

FDA Label Image

Figure C (Miudella 16)

Figure C (Miudella 16)
An instructional diagram of the Miudella intrauterine device (IUD), showing a 30 mm by 32 mm Nitinol frame with copper sleeves and attached retrieval threads for intrauterine placement.*
FDA Label Image

Figure D (Miudella 17)

Figure D (Miudella 17)
An illustration diagram showing the parts of the Miudella intrauterine device (IUD) insertion tool. It highlights the pre-loaded Miudella IUD, uterine depth markings on the insertion tube, flange, slider mechanism, position markings on the handle, and the end cap. The device is shown from both top and side views with labeled components.*
FDA Label Image

Figure (Miudella 18)

Figure (Miudella 18)
An instructional diagram of the Miudella intrauterine device showing labeled parts including copper sleeves, a nitinol frame, and a retrieval thread.*
FDA Label Image

Figure (Miudella 19)

Figure (Miudella 19)
An anatomical illustration showing female reproductive organs including the ovaries, uterus, and vagina. It depicts the Miudella intrauterine device (IUD) inserted inside the uterus, labeled accordingly to show its placement within the uterine cavity.*
FDA Label Image

Figure (Miudella 20)

Figure (Miudella 20)
An illustration showing a vertical arrow comparing levels of pregnancy frequency from 'More pregnancies' at the bottom to 'Fewer pregnancies' at the top. Various contraceptive methods are listed along the arrow, with intrauterine devices and sterilization at the top indicating fewer than 1 pregnancy per 100 women per year, birth control pills, injections, skin patch, and vaginal rings with hormones in the middle range, condoms and diaphragm lower, and no sex, spermicide, withdrawal, and no birth control near the bottom with higher pregnancy rates.*
FDA Label Image

Principal Display Panel (1 Tray Box)

Principal Display Panel (1 Tray Box)
Packaging label for Miudella copper intrauterine system, a prescription intrauterine device by Organon LLC. The label features the product name, copper intrauterine system, and indicates one sterile device with approximately 175 mm² copper surface area. The label includes usage and prescription information and the NDC 78206-210-01.*

* About these descriptions: Image descriptions on this page are generated by automated AI analysis of the product label images from the manufacturer's FDA label submission (SPL). They are provided for reference only and may contain errors or omissions. Always rely on the printed label itself and the official FDA labeling, and consult a pharmacist or healthcare professional with any questions about this product.