Symvess Implant
Product Images NDC 83564-110

View Photos of Packaging, Regulatory Labels, and Product Appearance

Product Visual Gallery

This gallery contains 17 technical images submitted to the FDA as part of the official labeling for Symvess (NDC 83564-110). Unlike standard consumer photos, these assets often include clinical data figures, molecular chemical structures, and official manufacturer packaging layouts.

As provided by Humacyte Global, Inc., these visuals offer a comprehensive scientific overview of the product's physical and chemical identity, aiding pharmacists and researchers in product verification and study.

FDA Label Image

Figure A (Symvess 01)

Figure A (Symvess 01)
Packaging label for Symvess, an acellular tissue engineered vessel implant by Humacyte Global, Inc. The box shows the product size as diameter 6mm and length 42cm. The packaging includes a FreezeAlert temperature indicator and notes single patient use for surgical vascular implantation. The NDC code 83564-110-01 is visible.*
FDA Label Image

Figure B (Symvess 02)

Figure B (Symvess 02)
An instructional illustration showing two panels of a FreezeAlert device. The left panel displays a device screen with a checkmark indicating 'OK' status; the right panel shows the device with an 'X' alarm status crossed out by a circle and diagonal line, indicating an incorrect or alarm condition to avoid.*
FDA Label Image

Figure C (Symvess 03)

Figure C (Symvess 03)
An instructional line drawing showing a gloved hand peeling back the seal of a rectangular sterile tray containing a Symvess acellular tissue engineered vessel implant. The tray label includes product name, strength, and manufacturer, Humacyte Global, Inc.*
FDA Label Image

Figure D (Symvess 04)

Figure D (Symvess 04)
An illustration showing a gloved hand opening a packaging tray containing Symvess acellular tissue engineered vessel implants. The tray appears to hold two labeled vials inside a molded compartment, suggesting sterile packaging for intravascular implant use.*
FDA Label Image

Figure E (Symvess 05)

Figure E (Symvess 05)
An illustration showing the Symvess implant inside a plastic thermoformed tray. The image labels key components including the Symvess acellular tissue engineered vessel, packaging bag, Dacron cuff, outer ports, middle ports, small outer port, and the plastic tray containing the device.*
FDA Label Image

Figure F (Symvess 06)

Figure F (Symvess 06)
An instructional illustration showing two healthcare professionals wearing gloves handling a long, narrow sterilized tray, possibly containing a vascular implant. One individual is holding the tray with both hands, while the other supports it from beneath, indicating careful preparation or transfer of the implant device.*
FDA Label Image

Figure G (Symvess 07)

Figure G (Symvess 07)
A black and white instructional diagram showing an acellular tissue engineered vessel implant with an instruction to cut at a specified location near the end of the vessel. The illustration includes a hand holding a cutting instrument positioned to cut the vessel tubing at the indicated point.*
FDA Label Image

Figure H (Symvess 08)

Figure H (Symvess 08)
An instructional diagram showing the handling of a tubular implant device, presumably the Symvess acellular tissue engineered vessel. The illustration depicts a gloved hand using scissors to cut a tied-off section at one end of the tubular implant, with an arrow and label indicating the cutting point.*
FDA Label Image

Figure I (Symvess 09)

Figure I (Symvess 09)
An instructional illustration showing a gloved person manipulating a long cylindrical medical device over a kidney-shaped basin, with drops falling from the device. The scene depicts handling or preparation of an implantable medical product, likely an intravascular implant such as Symvess acellular tissue engineered vessel.*
FDA Label Image

Figure J (Symvess 10)

Figure J (Symvess 10)
An instructional illustration showing a hand wearing a glove cutting a packaging bag containing an acellular tissue engineered vessel implant. The image has a label pointing to the cut location on the packaging bag.*
FDA Label Image

Figure K (Symvess 11)

Figure K (Symvess 11)
An instructional illustration showing a gloved hand cutting open a packaging bag containing an acellular tissue engineered vessel implant labeled 'CUT' on the packaging strip. The diagram includes an arrow and text instructing to "Cut the Packaging Bag this way," demonstrating the correct opening method.*
FDA Label Image

Figure L (Symvess 12)

Figure L (Symvess 12)
An instructional illustration showing two gloved hands opening the packaging of Symvess, an acellular tissue engineered vessel implant. The image depicts a pair of scissors cutting the packaging bag along a marked line labeled 'Cut the packaging bag here,' revealing the implant inside on a flat surface.*
FDA Label Image

Figure M (Symvess 13)

Figure M (Symvess 13)
An instructional diagram illustrating an acellular tissue engineered vessel implant, showing a gloved hand using scissors to cut the vessel at marked "Cut here" points. The diagram includes a close-up inset of a Dacron cuff at one end of the vessel, indicating precise handling for intravascular implantation.*
FDA Label Image

Figure N (Symvess 14)

Figure N (Symvess 14)
The image shows a clear medical packaging tray containing a curved, acellular tissue engineered vessel implant. The implant is tubular, white, and designed for intravascular use. This is consistent with Symvess, a 420 mm acellular tissue engineered vessel implant by Humacyte Global, Inc.*
FDA Label Image

Figure Q (Symvess 15)

Figure Q (Symvess 15)
A black and white line drawing showing a tubular implant with arrows pointing to the outer surface, illustrating the acellular tissue engineered vessel for intravascular use indicated by the product data for Symvess 420 mm implant by Humacyte Global, Inc.*
FDA Label Image

Principal Display Panel (Symvess 16)

Principal Display Panel (Symvess 16)
Packaging label for Symvess acellular tissue engineered vessel implant, size 6 mm diameter by 42 cm length. The label states it is for intravascular use, for single patient use only, and includes storage instructions and a FreezeAlert indicator. Manufactured by Humacyte Global, Inc.*
FDA Label Image

Principal Display Panel (Symvess 17)

Principal Display Panel (Symvess 17)
Label for Symvess acellular tissue engineered vessel implant by Humacyte Global, Inc. The label specifies size with a diameter of 6 mm and length of 42 cm. Storage instructions include keeping the product at 2°C to 8°C (36°F to 46°F) and not freezing. The label includes cautions such as 'DO NOT PUNCTURE' and notes the product is sterile and for prescription use only.*

* About these descriptions: Image descriptions on this page are generated by automated AI analysis of the product label images from the manufacturer's FDA label submission (SPL). They are provided for reference only and may contain errors or omissions. Always rely on the printed label itself and the official FDA labeling, and consult a pharmacist or healthcare professional with any questions about this product.