INSTRUCTIONS FOR USE
Tobramycin Inhalation Solution (toe-brah-MYE-sin)
for oral inhalation use
Read this Instructions for Use before you start using tobramycin inhalation solution inhalationsolution and each time you get a refill. There may be new information. This leaflet does not takethe place of talking to your healthcare provider about your medical condition or treatment.
Tobramycin inhalation solution is made for inhalation using a PARI LC PLUS™ ReusableNebulizer and a DeVilbiss® Pulmo-Aide® air compressor. Tobramycin inhalation solution can betaken at home, school, or at work. The following instructions tell you how to use the DeVilbissPulmo-Aide air compressor and PARI LC PLUS Reusable Nebulizer to administer tobramycininhalation solution.
You will need the following supplies (See Figure A):
1 tobramycin inhalation solution plastic ampule (tobramycin inhalation solution ispackaged with 4 ampules in each foil pouch)
DeVilbiss Pulmo-Aide air compressor
PARI LC PLUS Reusable Nebulizer
Tubing to connect the nebulizer and compressor
Clean paper or cloth towels
Nose clips (optional)
(Figure A)
It is important that your nebulizer and compressor function properly before starting yourtobramycin inhalation solution therapy.
Note: Read the manufacturer care and use instructions for important information.
Prepare Your Tobramycin Inhalation Solution for Inhalation Therapy
Step 1: Wash your hands thoroughly with soap and water.
Step 2: Open the foil pouch.Step 3: Separate 1 tobramycin inhalation solution ampule by gently pulling apart at the bottomtabs (See Figure B). Place the remaining tobramycin inhalation solution ampules in therefrigerator.
(Figure B)
Step 4: Check the expiration date stamped on the tobramycin inhalation solution ampule (See FigureC). Do not use the tobramycin inhalation solution ampule if the expiration date has passed.
(Figure C)
Step 5: Check that the tobramycin inhalation solution ampule medicine is clear and does nothave particles.
Unrefrigerated tobramycin inhalation solution, which is normally slightly yellow, maydarken with age. This color change does not mean there is any change in the quality ofthe medicine.
Do not use the tobramycin inhalation solution ampule if the medicine is cloudy or hasparticles.
Throw it away and get a new one.Step 6: Lay out the parts of a PARI LC PLUS Reusable Nebulizer package on a clean, dry paperor cloth towel. You should have the following parts (See Figure D):
Nebulizer Top and Bottom (Nebulizer Cup) Assembly
Inspiratory Valve Cap
Mouthpiece with Valve
Tubing
(Figure D)
Step 7: Remove the Nebulizer Top from the Nebulizer Cup by twisting the Nebulizer Topcounter-clockwise, and then lifting off (See Figure E).
(Figure E)
Step 8: Place the Nebulizer Top on the clean paper or cloth towel by standing the Nebulizer Cupupright on the towel (See Figure F).
(Figure F)
Step 9: Connect one end of the tubing to the compressor air outlet (See Figure G). The tubingshould fit tightly.
(Figure G)
Step 10: Plug in your compressor to an electrical outlet (See Figure H).
(See Figure H).
Step 11. Open the tobramycin inhalation solution ampule by holding the bottom with one handand twisting off the top of the ampule with the other hand as indicated by the arrow (See FigureI). Be careful not to squeeze the ampule until you are ready to empty its contents into theNebulizer Cup.
(Figure I)
Step 12: Squeeze all the medicine of the tobramycin inhalation solution ampule into the Nebulizer Cup (See Figure J).
(Figure J)
Step 13: Replace the Nebulizer Top. To replace the Nebulizer Top insert the Nebulizer Top into the Nebulizer Cup with the semi-circle halfway down the stem of the Nebulizer Top facing the Nebulizer Outlet. Turn the Nebulizer Top clockwise until securely fastened to the nebulizer Cup. (See Figure K).
(Figure K)
Step 14: Push the Mouthpiece straight onto the Nebulizer Outlet (See Figure L).
(Figure L)
Step 15: Firmly push the Inspiratory Valve Cap straight down onto the Nebulizer Top (See Figure M). The Inspiratory Valve Cap will fit tightly.
(Figure M)
Step 16: Hold the Nebulizer Cup upright and firmly push the free end of the tubing from thecompressor to the Air Intake on the bottom of the Nebulizer Cup (See Figure N).
Make sure tokeep the Nebulizer Cup upright.
(Figure N)
Giving your Tobramycin Inhalation Solution Inhalation Therapy
Step 17: Turn on the compressor (See Figure O).
(Figure O)
Step 18: Check for a steady mist from the Mouthpiece (See Figure P). If there is no mist, checkall tubing connections and make sure that the compressor is working properly.
(Figure P)
Step 19: Sit or stand in an upright position that will allow you to breathe normally.Place the Mouthpiece between your teeth and on top of your tongue and breathe normally onlythrough your mouth (See Figure Q). Nose clips may help you breathe through your mouth andnot through your nose. Do not block the airflow with your tongue.
(Figure Q)
Step 20: Keep breathing in your tobramycin inhalation solution medicine for at least 15 minutes to get your full dose. Continue therapy until all your tobramycin inhalation solution medicine is gone, and there is no longer any mist being made.
You may hear a sputtering sound coming from the Mouthpiece when the Nebulizer Cup is empty. The entire tobramycin inhalation solution therapy should take about 15 minutes to complete.
If you are interrupted, need to cough or rest during your tobramycin inhalation solution treatment, turn off the compressor to save your medicine.
Turn the compressor back on when you are ready to restart your treatment.
Follow the nebulizer cleaning and disinfecting instructions after completing your therapy.
After your Tobramycin Inhalation Solution Inhalation Therapy
Cleaning Your Nebulizer
To reduce the risk of infection, illness or injury from contamination, you must thoroughly clean all parts of the nebulizer as instructed after each treatment. Never use a nebulizer with a clogged nozzle. If the nozzle is clogged, no aerosol mist is made, and your therapy will not be as effective. Replace the nebulizer if clogging occurs.
1. Remove tubing from nebulizer and disassemble nebulizer parts.
2. Wash all parts (except tubing) with warm water and liquid dish soap.
3. Rinse thoroughly with warm water and shake out water.
4. Air dry or hand dry nebulizer parts on a clean, lint-free cloth. Reassemble nebulizer when dry, and store. You can also wash all parts of the nebulizer in a dishwasher (except tubing). 1. Place the nebulizer parts in a dishwasher basket. 2. Place the dishwasher basket on the top rack of the dishwasher. 3. Remove and dry the parts when the cycle is complete.
Disinfecting Your Nebulizer
Your nebulizer is for your use only. Do not share your nebulizer with other people. You must disinfect the nebulizer every other treatment day. Failure to disinfect the nebulizer every other treatment day could lead to serious or fatal illness.
Clean the nebulizer as described above. Every other treatment day, disinfect the nebulizer parts (except tubing) by boiling them in water for a full 10 minutes. Dry parts on a clean, lint-free cloth.
Care and Use of Your Pulmo-Aide Compressor
Follow the manufacturers instructions for care and use of your compressor.
Filter Change: Follow the manufacturer instructions for care and use of your compressor.
Filter Change:
· DeVilbiss Compressor filters should be changed every 6 months or sooner if the filter turns completely gray in color.
Compressor Cleaning:
· With power switch in the “Off” position, unplug power cord from wall outlet.
· Wipe outside of the compressor cabinet with a clean, damp cloth every few days to keep dust free.Caution: Do not submerge in water because this will damage the compressor.
How should I store tobramycin inhalation solution?
· Store tobramycin inhalation solution ampules in a refrigerator between 36°F to 46°F (2°C to 8°C) until needed.
· You may store the tobramycin inhalation solution ampules in the foil pouches (opened or unopened) at room temperature 77°F (25°C) for up to 28 days.
Do not use tobramycin inhalation solution ampules if they have been stored at room temperature for more than 28 days.
· Protect tobramycin inhalation solution ampules from light.
Keep tobramycin inhalation solution and all medicines out of the reach of children.
This Instructions for Use has been approved by the U.S. Food and Drug Administration.
Additional Information
Nebulizer: 1-800-327-8632
Compressor: 1-800-338-1988
Tobramycin Inhalation Solution: 1-888-375-3784
Brands listed are trademarks of their respective owners.
Rx Only
Manufactured by:
Holopack Verpackungstechnik GmbH
Bahnhofstrasse 20
73453 Abtsgmünd-Untergröningen
Germany
Distributed by: