NDC 53877-008 Teruflex Blood Bag System With Diversion Blood Sampling Arm Anticoagulant Citrate Phosphate Dextrose (cpd) And Optisol (as-5) Red Cell Preservative

View Dosage, Usage, Ingredients, Routes, UNII

Product Information

This product is EXCLUDED from the official NDC directory because the listing data was inactivated by the FDA.

Get all the details for National Drug Code (NDC) 53877-008 in one place. This page breaks down everything you need to know about the NDC, including proprietary name, active and inactive substances, package configurations, billing units, labeler information, and routes of administration. It also includes enhanced data such as HCPCS codes, FDA product labels with images, UNIIs, and RxNorm cross-references. Whether you're a healthcare professional verifying drug data or a consumer researching medication, this NDC page helps you make informed, accurate decisions.

NDC Product Code:
53877-008
Proprietary Name:
Teruflex Blood Bag System With Diversion Blood Sampling Arm Anticoagulant Citrate Phosphate Dextrose (cpd) And Optisol (as-5) Red Cell Preservative
Product Type: [3]
INACTIVATED PRODUCT and EXCLUDED the from NDC Directory
Labeler Name: [5]
Labeler Code:
53877
FDA Application Number: [6]
BN880217
Marketing Category: [8]
NDA - A product marketed under an approved New Drug Application.
Start Marketing Date: [9]
05-05-2010
Listing Expiration Date: [11]
12-31-2024
Exclude Flag: [12]
I
Code Navigator:

Code Structure Chart

Product Details

What is NDC 53877-008?

The NDC code 53877-008 is assigned by the FDA to the product Teruflex Blood Bag System With Diversion Blood Sampling Arm Anticoagulant Citrate Phosphate Dextrose (cpd) And Optisol (as-5) Red Cell Preservative which is product labeled by Terumo Corporation. The product's dosage form is . The product is distributed in 4 packages with assigned NDC codes 53877-008-51 24 bag in 1 case / 1 kit in 1 bag * 63 ml in 1 bag * 100 ml in 1 bag, 53877-008-61 24 bag in 1 case / 1 kit in 1 bag * 70 ml in 1 bag * 111 ml in 1 bag, 53877-008-71 18 bag in 1 case / 1 kit in 1 bag * 70 ml in 1 bag * 111 ml in 1 bag, 53877-008-81 18 bag in 1 case / 1 kit in 1 bag * 63 ml in 1 bag * 100 ml in 1 bag. This page includes all the important details about this product, including active and inactive ingredients, pharmagologic classes, product uses and characteristics, UNII information and RxNorm crosswalk.

What are the uses for Teruflex Blood Bag System With Diversion Blood Sampling Arm Anticoagulant Citrate Phosphate Dextrose (cpd) And Optisol (as-5) Red Cell Preservative?

Issued 6/03 TERUFLEX® BLOOD BAG SYSTEM With DIVERSION BLOOD SAMPLING ARM® CPD/OPTISOL® SOLUTIONRead these instructions carefully before use. Rx ONLY.The Diversion Blood Sampling Arm™ is intended to divert and collect blood for obtaining donor test samples.• For single use only. Sterile and non-pyrogenic fluid path. Sterilized by steam.• Intended for the collection, processing and preservation of human blood and components.PRECAUTIONS• Do not use unless the solutions are clear.• Avoid excessive heat and direct sunlight. Protect from freezing.• Recommended storage conditions: Room Temperature (15-30°C/59-86°F).• The blood bag configuration is specified on the blister pack label.CAUTION Do not use a dielectric tube sealer to seal the tubing while the needle is connected to the donor's body unless it is approved for such a purpose.INSTRUCTIONS FOR BLOOD COLLECTION: Use aseptic techniqueMaterials Needed: VENOJECT® ll Tube Holder (code P-1316R) or equivalentVENOJECT® ll Multi-Sample Luer Adapter (code MN *2000T) or equivalentEvacuated Blood Collection Tubes (glass or plastic)1. Prepare the blood bag following your institution's standard operating procedures.2. If applicable, make a loose knot in the donor tubing below the "Y" and CLIKTIP™ (inline closure device) unless alternate methods are used to seal the tubing at the end of collection.3. Temporarily clamp the donor tubing between the phlebotomy needle and the "Y".4. Close the White Clamp below the diversion pouch.5. Tube Holder/Luer Adapter Assembly:a) Connect the VENOJECT II Multi-Sample Luer Adapter to the VENOJECT II Tube Holder (or equivalent) (Fig.1).Insert Fig. 1 hereb) Twist and snap to remove the blue port cap at the end of the Diversion Blood sampling Arm (Fig. 2a).c) Connect the multi-sample luer adapter to the female luer port. (Fig. 2b)NOTE: Alternatively, steps a, b and c (above) may be performed at any time during bag preparation or after the blood is collected into the diversion pouch.Insert Fig. 2a and 2b here6. Suspend the collection bag as far as possible below the donor's arm.7. Apply blood pressure cuff or tourniquet to donor's arm. Disinfect site of phlebotomy. If blood pressure cuff is used, inflate to approximately 60 mmHg.8. Remove the needle cover and perform phlebotomy. Remove the temporary clamp on the donor tubing to permit blood flow into the Diversion Blood Sampling Arm pouch.CAUTION Do not touch the needle after removing the needle protector. Assure that the White Clamp below the pouch is closed prior to initiating phlebotomy.9. If using a needle safety device, follow the manufacturer's instructions to secure the device in place.10. Appropriately secure donor tubing to donor's arm.11. Position the diversion pouch with the notches up and the Tube Holder/Luer Adapter assembly (or port cap) down. When the level of blood in the pouch is approximately in linewith the notches, the diversion pouch is full. (Fig. 3a)NOTE: The approximate fill volume of the pouch at the notches is 35 mL.12. Permanently seal the tubing between the "Y" and the diversion pouch to maintain a closed system using an aluminum clip or a tube sealer approved for use with tubing connected to a donor. (Fig. 3b)13. To initiate blood flow into the collection bag, break the CLlKTIP between the "Y" and the primary bag.14. To avoid clot formation, collect samples as soon as possible from the diversion pouch as follows (Fig. 3b)CAUTION Do not collect donor test samples until the tubing between the "Y" and the diversion pouch is permanently sealed.a) Open the White Clamp on the tubing below the pouch to open the pathway for sampling.b) Position the diversion pouch with the notches up and the Tube Holder/Luer Adapter assembly down. Assure that any air in the pouch is at the top and will not enter theblood collection tubes.c) Insert vacuum blood collection tube firmly into the tube holder; when full, remove sample tube from holder. Repeat to collect additional samples.NOTE: The pouch may be removed after the donor test samples are collected. A second seal must be made between the diversion pouch and the permanent sealprior to removing the pouch.Insert Fig. 3a and 3b here15. Once samples are obtained, mix blood with anticoagulant in the primary bag and continue to mix at several intervals during collection. 16. Collect labeled volume of blood (+/–10%).17. When the desired amount of blood has been collected, seal the tubing or tighten the loose knot (white knot) prepared in step 2. Make a second seal between the first seal or knot andthe CLlKTIP below the "Y". Various methods may be used to seal tubing.18. Release pressure on the donor's arm and remove the needle. If using a needle safety device, follow the manufacturer's instructions to remove the needle. Sever the donor tubing between the two seals previously made below the CLlKTIP and "Y".CAUTION Discard the Diversion Blood Sampling Arm and phlebotomy needle/donor tubing according to institutional procedures.19. Immediately after collection, invert the bag several times to assure blood and anticoagulant are well mixed.20. Strip blood from the donor tubing into the bag, mix well, and allow tubing to refill. Seal on or near the X marks on the donor tubing to provide numbered aliquots of anticoagulated blood for testing.21. The time of addition of OPTISOL Solution may vary depending on the processing option selected. Add the solution under one of the following conditions after removal of plasma:a) Within 8 hours of whole blood collection, if components are prepared.b) Within 72 hours of collection if whole blood is refrigerated immediately following collection.22. Centrifuge the unit to separate red cells from plasma.23. Break the CLlKTIP of primary collection bag and transfer the plasma into the satellite bag. Clamp transfer tubing of satellite bag.24. Break the CLlKTIP of OPTlSOL Solution bag and drain contents into primary bag containing red blood cells. Seal tubing of primary bag in two places, and cut between sealsand separate from satellite bag(s).NOTE: For TERUFLEX double bags, seal OPTISOL Solution bag tubing in two places and cut between seals. Discard OPTISOL Solution container.25. Invert the red cell- OPTISOL mixture several times to insure the final AS-5 red cell product is well suspended.26. Store AS-5 Red Blood Cells between 1-6°C.27. Infuse AS-5 Red Blood Cells within 42 days of collection.For further processing, use standard component processing techniques.To open blister package, peel cover film back four fifths of its length. After opening, unused bags may be stored for 30 days by returning cover film to original position and sealing with tape to prevent possible loss of moisture.Insert Fig. 4 hereCAUTIONS•The packet of AGELESS contained in this package absorbs oxygen and generates heat on removal. Handle it with care.• Dispose with packet in tray.• Do not dispose with wastes containing volatile or flammable materials.• Discard AGELESS packet without opening.N-BB-OP-A2(DB) 1TERUMO® MANUFACTURED BY: TERUMO CORPORATION 44-1, 2-CHOME, HATAGAYA, SHIBUYA-KU, TOKYO, JAPAN MADE IN JAPAN®: Registered Trademark Diversion Blood Sampling Arm and CLIKTIP are trademarks of TERUMO CORPORATION.© TERUMO CORPORATION 2003 03F10

Which are Teruflex Blood Bag System With Diversion Blood Sampling Arm Anticoagulant Citrate Phosphate Dextrose (cpd) And Optisol (as-5) Red Cell Preservative UNII Codes?

The UNII codes for the active ingredients in this product are:

Which are Teruflex Blood Bag System With Diversion Blood Sampling Arm Anticoagulant Citrate Phosphate Dextrose (cpd) And Optisol (as-5) Red Cell Preservative Inactive Ingredients UNII Codes?

The inactive ingredients are all the component of a medicinal product OTHER than the active ingredient(s). The acronym "UNII" stands for “Unique Ingredient Identifier” and is used to identify each inactive ingredient present in a product. The UNII codes for the inactive ingredients in this product are:

* Please review the disclaimer below.

Product Footnotes

[5] What is the Labeler Name? - Name of Company corresponding to the labeler code segment of the Product NDC.

[6] What is the FDA Application Number? - This corresponds to the NDA, ANDA, or BLA number reported by the labeler for products which have the corresponding Marketing Category designated. If the designated Marketing Category is OTC Monograph Final or OTC Monograph Not Final, then the Application number will be the CFR citation corresponding to the appropriate Monograph (e.g. “part 341”). For unapproved drugs, this field will be null.

[8] What is the Marketing Category? - Product types are broken down into several potential Marketing Categories, such as NDA/ANDA/BLA, OTC Monograph, or Unapproved Drug. One and only one Marketing Category may be chosen for a product, not all marketing categories are available to all product types. Currently, only final marketed product categories are included. The complete list of codes and translations can be found at www.fda.gov/edrls under Structured Product Labeling Resources.

[9] What is the Start Marketing Date? - This is the date that the labeler indicates was the start of its marketing of the drug product.

[11] What is the Listing Expiration Date? - This is the date when the listing record will expire if not updated or certified by the product labeler.

[12] What is the NDC Exclude Flag? - This field indicates whether the product has been removed/excluded from the NDC Directory for failure to respond to FDA"s requests for correction to deficient or non-compliant submissions, or because the listing certification is expired, or because the listing data was inactivated by FDA, or because it was discontinued by the labeler. Possible values in this field are: "D", "E", "I", "N", "U".