Oxygen
FDA Label NDC 65700-1649

Full FDA labeling including Indications, Dosage, Usage, and Precautions

Structured Product Label

The following Structured Product Label (SPL) was submitted to the FDA by Major Medical Supply Llc for the product Oxygen (NDC 65700-1649). This document serves as the official prescribing information, containing essential scientific data and clinical materials required for healthcare providers and patients.

This specific version of the label includes detailed information regarding oxygen compressed usp product label, oxygen refrigerated liquid usp product label, and other regulatory disclosures. Use the navigation below to review specific sections of the FDA submission.

Oxygen Compressed Usp Product Label

OXYGEN COMPRESSED USP UN 1072

OXYGEN-2

DANGER:

COMPRESSED, OXIDIZING GAS, MAY CAUSE OR INTENSIFY FIRE; OXIDIZER, CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED.
In case of fire: stop leak if safe to do so. Keep reduction valves free from grease and oil. Open valve slowly. Store and use in a well ventilated place. Use a back flow preventive device in the piping. Close valve after after each use and when empty. Protect from sunlight when ambient temperature exceeds 52° C/125° F. Container temperature should not exceed 52° C/125° F. Do not handle until all safety precautions have been read and understood. Keep/store away from combustible materials. Use only with equipment cleaned for oxygen service and rated for cylinder pressure.

DO NOT REMOVE THIS PRODUCT LABEL.

For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications, Rx only.

Uninterrupted use of high concentrations of oxygen over a long duration, without monitoring its effect on oxygen content of arterial blood, may be harmful. Use only with pressure reducing equipment and apparatus designed for oxygen. Do not attempt to use on patents who have stopped breathing unless used in conjunction with resuscitative equipment. Produced by Air Liquefaction

Contents
Size
170 Liters
M6
248 Liters
C
415 Liters
D
682 Liters
E
6910 Liters
H
____________ Liters
Other



CAS NO: 7782-44-7

Major Medical Supply
1649 Main Street
Longmont, CO 80501
(303) 651-6400

Majormed Hp O2  Label (Majormed Hp O2)

Majormed Hp O2 Label (Majormed Hp O2)

Oxygen Refrigerated Liquid Usp Product Label

OXYGEN REFRIGERATED LIQUID USP    UN 1073

OXYGEN 2

CONTENTS: ___________________ LITERS

CAS NO:7782-44-7

DANGER:

REFRIGERATED LIQUEFIED OXIDIZING GAS. ALWAYS KEEP CONTAINER IN UPRIGHT POSITION. DO NOT CHANGE OR FORCE FIT CONNECTIONS. MAY CAUSE OR INTENSIFY FIRE: OXIDIZER. CONTAINS REFRIGERATED GAS: MAY CAUSE CRYOGENIC BURNS OR INJURY. COMBUSTIBLES IN CONTACT WITH LIQUID OXYGEN MAY EXPLODE ON IGNITION OR IMPACT.

Do not get into eyes, on skin, or on clothing. Keep reduction valves free from grease and oil. In case of fire, stop leak if safe to do so. Avoid spills. Do not walk or roll equipment over spills. Store and use in a well ventilated place. use only with equipment of compatible materials of construction and rated for cylinder pressure. Wear cold insulating gloves/face shield/eye protection. Protect from sunlight when ambient temperature exceeds 52° C/125° F. Container temperature should not exceed 52° C/125° F. Close valve after each use and when empty. Use a back flow preventive device in the pipping. Do not handle until all safety precautions have been read and understood. Use only with equipment cleaned for oxygen service.  Keep/store away from combustible materials. Do not drop. Use suitable hand truck for container movement.

FIRST AID:

IN CASE OF FROSTBITE: Thaw frosted parts with lukewarm water. Do not rub affected area. Get immediate medical advise/attention.

DO NOT REMOVE THIS PRODUCT LABEL

For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications, Rx only. Uninterrupted use of high concentrations of oxygen over a long duration, without monitoring its effect on oxygen content of arterial blood, may be harmful. Use only with pressure reducing equipment and apparatus designed for oxygen. Do not attempt to use on patients who have stopped breathing unless used in conjunction with resuscitative equipment. Produced by Air Liquefaction.

ALWAYS KEEP CONTAINER IN UPRIGHT POSITION

Major Medical Supply
1649 Main Street
Longmont, CO 80501
(303) 651-6400

Majormed Liq O2 Label (Majormed Liq O2)

Majormed Liq O2 Label (Majormed Liq O2)


* Please review the disclaimer below.